OSHA Inspection: ALEXIS MARTINEZ

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALEXIS MARTINEZ in 5803 SUGAR HILL DR., HOUSTON, TX 77057 (NAICS 238170). OSHA activity number 348036997.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alexis Martinez — free Get an email when a new federal OSHA severe-injury report for Alexis Martinez is published. One employer, no account, unsubscribe in one click.
Establishment
ALEXIS MARTINEZ
Site address
5803 SUGAR HILL DR.
City
HOUSTON
State
TX
ZIP
77057
Mailing
307 MASTERSON ST., ARCOLA, TX 77583
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 1, 2025
Abate by
Apr 9, 2025
Penalty
Initial $4,965 · Current $2,979 Reduced
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:   a) On or about February 10, 2025, on the roof of a two-story building, employees worked near an energized powerline while carrying an aluminum rain gutter.
Recent events (2)
  • — I (S) $2979
  • — Z (S) $4965

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 1, 2025
Abate by
Apr 9, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take.   a) On or about February 10, 2025, on the roof of a two-story building, the employer did not post warning signs to alert employees of energized powerlines, nor were protective measures advised to employees carrying aluminum rain gutters near energized powerlines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2025
Abate by
Apr 9, 2025
Penalty
Initial $3,547 · Current $2,128 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On or about February 10, 2025, on the roof of a two-story building, employees removed and carried rain gutters at heights greater than 6 feet above lower levels without a fall protection system.
Recent events (2)
  • — I (S) $2128.2
  • — Z (S) $3547

View Alexis Martinez's full OSHA safety record →