JACKSONVILLE, FL —
OSHA Inspection: JINKO SOLAR U.S. INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JINKO SOLAR U.S. INDUSTRIES, INC. in 4660 NEW WORLD AVENUE #200, JACKSONVILLE, FL 32221 (NAICS 335999). OSHA activity number 348040841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JINKO SOLAR U.S. INDUSTRIES, INC.
- Site address
- 4660 NEW WORLD AVENUE #200
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32221
- Mailing
- 4660 POW-MIA MEMORIAL PARKWAY SUITE 200, JACKSONVILLE, FL 32221
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 600
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 24, 2025
- Penalty
- Initial $9,457 · Current $6,150 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. Back Glass Area; On or about February 8, 2025, the employee clearing a jam on the EVA Gasket Cutter on line #2 was not provided with procedures, exposing the employee to an amputation hazard.
Recent events (2)
- — I (S) $6150
- — Z (S) $9457
1910.147 C07 I A
- Issued
- Mar 24, 2025
- Abate by
- Apr 17, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. Back Glass Area; On or about February 8, 2025, the employer didn't train the employee that was clearing the jam out of the EVA Gasket Cutter on line #2 as an authorized employee, exposing the employee to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 M07
- Issued
- Mar 24, 2025
- Penalty
- Initial $9,457 · Current $6,150 Reduced
General-duty citation text
29 CFR 1910.178(m)(7): Brakes were not set and/or wheel blocks were not in place to prevent movement of trucks, trailers, or railroad cars while loading and unloading: a. At the dock: On or about February 28, 2025, the employer failed to block trailer wheels to prevent trucks' movements, exposing the employees who drove forklifts into the trailers to a crushed-by hazard.
Recent events (2)
- — I (O) $6150
- — Z (S) $9457
1910.176 A
- Issued
- Mar 24, 2025
- Abate by
- Apr 17, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(a): Permanent aisles or passageways were not appropriately marked: a. At the loading and unloading dock area and throughout: On or about February 28, 2025, permanent walkways and employee travel lanes were not established and appropriately marked, exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 24, 2025
- Penalty
- Initial $9,457 · Current $6,150 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Back Glass Area; On or about February 8, 2025, the employer exposed an employee to an amputation hazard, in that the EVA Gasket Cutter on line #2 didn't have a guard that prevented the employee from reaching into the machine while in operation.
Recent events (2)
- — I (S) $6150
- — Z (S) $9457
More inspections at Jinko Solar U.S. Industries, INC.
View Jinko Solar U.S. Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348040841.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.