Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KUTZNER MANUFACTURING CO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KUTZNER MANUFACTURING CO in 3255 MEETINGHOUSE ROAD, TELFORD, PA 18969 (NAICS 332999). OSHA activity number 348041732.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kutzner Manufacturing CO — free Get an email when a new federal OSHA severe-injury report for Kutzner Manufacturing CO is published. One employer, no account, unsubscribe in one click.
Site address
3255 MEETINGHOUSE ROAD
City
TELFORD
State
PA
ZIP
18969
Mailing
3255 MEETINGHOUSE ROAD, TELFORD, PA 18969
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 11, 2025
Abate by
Jul 30, 2025
Penalty
Initial $2,837 · Current $1,702 Reduced
29 CFR  1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  a) 3255 Meetinghouse Road Telford, PA 18969- On or about February 13, 2025, the employer did not certify that employee training for lockout/tagout had been accomplished.
Recent events (2)
  • — I (S) $1702.2
  • — Z (S) $2837

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 11, 2025
Abate by
Jul 30, 2025
Penalty
Initial $2,837 · Current $1,702 Reduced
29 CFR  1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) 3255 Meetinghouse Road Telford, PA 18969- On or about February 13, 2025, an employee working on the shop floor was exposed to compressed air that was measured to be above 92 PSI while they were cleaning metal shavings off a horizontal mill.
Recent events (2)
  • — I (S) $1702.2
  • — Z (S) $2837

1904.33 A

Other-than-serious 1 instance 2 exposed
Issued
Jul 11, 2025
Abate by
Jul 30, 2025
Penalty
Initial $946 · Current $568 Reduced
29 CFR  1904.33(a):The employer did not save the OSHA 300 Log, the privacy case list (if one existed), the annual summary, and the OSHA 301 Incident Report Forms for five (5) years following the end of the calendar year that these records covered.  a) 3255 Meetinghouse Road Telford, PA 18969- On or about February 13, 2025, the employer failed to maintain the annual summary for the past three years.
Recent events (2)
  • — I (O) $567.6
  • — Z (O) $946

View Kutzner Manufacturing CO's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348041732.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.