Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERMO BOND BUILDINGS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERMO BOND BUILDINGS, LLC in 1001 WEST MAIN STREET, ELK POINT, SD 57025 (NAICS 321992). OSHA activity number 348041880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermo Bond Buildings, LLC — free Get an email when a new federal OSHA severe-injury report for Thermo Bond Buildings, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1001 WEST MAIN STREET
City
ELK POINT
State
SD
ZIP
57025
Mailing
1001 WEST MAIN STREET, ELK POINT, SD 57025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321992
Employees
300
Ownership type
A

1 citation on file for this inspection.

1910.1053 D01

Other-than-serious 1 instance 3 exposed
Issued
May 23, 2025
Abate by
Jun 26, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1053(d)(1): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section:  (a)Thermo Bond Buildings, LLC. at 1001 West Main Street, Elk Point, SD 57025: On or about and at times prior to February 13, 2025, the employer did not perform a hazard assessment for respirable crystalline silica exposure as employees were performing residual concrete removal from pre-cast concrete walls.  This condition exposed employees to potential over exposure to respirable crystalline silica.
Recent events (1)
  • — Z (O) $0

View Thermo Bond Buildings, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348041880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.