OSHA Inspection: MUELLER SUPPLY COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MUELLER SUPPLY COMPANY, INC. in 1913 HUTCHINS AVENUE, BALLINGER, TX 76821 (NAICS 332311). OSHA activity number 348045352.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mueller Supply Company, INC. — free Get an email when a new federal OSHA severe-injury report for Mueller Supply Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1913 HUTCHINS AVENUE
City
BALLINGER
State
TX
ZIP
76821
Mailing
1913 HUTCHINS AVENUE ATTN: BILL HUNTER, BALLINGER, TX 76821
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
237
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 10 1 instance 9 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:   On or about February 13, 2025, and at times prior thereto and thereafter, energy control procedures developed by the employer did not clearly outline the scope and purpose of the procedure, the detailed techniques and/or steps to isolate each energy source, and/or the requirements to test or enforce the effectiveness of the energy control measures, exposing employees to the hazards of unexpected energization, start-up of machinery and/or equipment, or release of stored energy.
Recent events (3)
  • — F (S) $0
  • — C (S) $16550
  • — Z (S) $16550

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  On or about February 13, 2025 and at times prior thereto and thereafter, in the prefab area, the bandsaw machinist performed maintenance and servicing work without being provided the training of an authorized employee.
Recent events (3)
  • — F (S) $0
  • — C (S) $16550
  • — Z (S) $16550

1910.252 B02 III

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $14,187 · Current $0 Reduced
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  On or about May 8, 2025, and at times prior thereto, in the prefab area, welding screens or shields were not utilized while employees performed welding work.
Recent events (3)
  • — F (S) $0
  • — C (S) $14187
  • — Z (S) $14187

1910.253 B02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  On or about February 13, 2025, and at times prior thereto, in the prefab area, Liquid Oxygen tanks were stored next to bay doors used for transporting material in and out of the building without being protected from being struck-by material handling equipment.
Recent events (3)
  • — F (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1910.253 B04 III

Deleted Serious Gravity 10 2 instances 12 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $16,550 · Current $0 Reduced

Hazardous substances X100

29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:   On or about February 13, 2025, and at times prior thereto, oxygen cylinders were not separated from fuel-gas cylinders or other combustible materials by distance or noncombustible barriers in the follow areas:  a) In the compressed gas storage area; b) Prefab work area.
Recent events (3)
  • — F (S) $0
  • — C (S) $16550
  • — Z (S) $16550

1910.303 G01

Deleted Other-than-serious 2 instances 3 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $1,328 · Current $0 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about February 13, 2025, and at times prior thereto, electrical disconnect panels in the prefab area were obstructed and were not provided sufficient access/working space around the electrical panels.
Recent events (3)
  • — F (O) $0
  • — C (O) $1328
  • — Z (O) $1328