Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ESTRADA DESIGN AND MACHINE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ESTRADA DESIGN AND MACHINE, LLC in 6409 N 50TH ST, TAMPA, FL 33610 (NAICS 337212). OSHA activity number 348046988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Estrada Design and Machine, LLC — free Get an email when a new federal OSHA severe-injury report for Estrada Design and Machine, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6409 N 50TH ST
City
TAMPA
State
FL
ZIP
33610
Mailing
8303 NORTH 46TH ST, TAMPA, FL 33617
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
15
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 15 exposed
Issued
Jun 11, 2025
Penalty
Initial $6,620 · Current $3,972 Reduced
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to struck by and crushing hazards, in that warehouse storage racks containing sheets of wood and materials were not secured and anchored to the floor  while employees are performing warehouse shipping and receiving operations
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

1910.107 B09

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 11, 2025
Penalty
Initial $4,729 · Current $2,837 Reduced
29 CFR  1910.107(b)(9):Spray booths were not so installed that all portions are readily accessible for cleaning:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to fire and tripping hazards, in that,  3ft of adequate and clear space on all sides of exterior of the spray booth tent was not provided for employees.
Recent events (2)
  • — I (S) $2837.4
  • — Z (S) $4729

1910.107 D02

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $5,675 · Current $3,405 Reduced
29 CFR  1910.107(d)(2):Spraying areas were not provided with adequate mechanical ventilation to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered. Mechanical ventilation was not kept in operation at all times while spraying operations were being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to respiratory illness, in that, mechanical ventilation to remove flammable vapors, mists, or powders to a safe location was not provided for employees while spray painting in a interior paint booth.
Recent events (2)
  • — I (S) $3405
  • — Z (S) $5675

1910.134 C01

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $3,783 · Current $2,270 Reduced
29 CFR  1910.134(c)(1):The respiratory protection program was not updated as necessary to reflect those changes in workplace conditions that affected respirator use as specified in paragraphs (c)(1)(i)-(c)(1)(ix) of the standard:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to respiratory illness in that a written respiratory protection program was not established or implemented for the required use of  3M - N95 Particulate Respirator while spray painting.
Recent events (2)
  • — I (S) $2269.8
  • — Z (S) $3783

1910.134 E01

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a.) a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to respiratory illness, in that, employer did not ensure that employees required to wear tight-fitting respirators for spray painting operations were provided a medical evaluation to determine their ability to use respirators in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k):The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to respiratory illness, in that,  the employer did not ensure that employees who utilized respirators, were trained prior to wearing respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 11, 2025
Penalty
Initial $6,620 · Current $3,972 Reduced
29 CFR  1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to struck by hazards; in that, forklift operations were conducted without formal instruction, hands on trainings, evaluations and certifications in place while operating an electrical forklift moving merchandise and products in the front and back lots of the warehouse.
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

1910.303 G01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 11, 2025
Penalty
Initial $3,783 · Current $2,270 Reduced
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to fire and electric shock hazards, in that the front of electrical panels, located in the warehouse, were obstructed by a work desk, boxes, crates and tools while retrieving merchandise.
Recent events (2)
  • — I (S) $2269.8
  • — Z (S) $3783

1910.305 B01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $2,837 · Current $1,702 Reduced
29 CFR  1910.305(b)(1)(i):Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to fire and electric shock hazards, in that  cords installed within the distribution panel were not protected with strain reliefs and box connectors.
Recent events (2)
  • — I (S) $1702.2
  • — Z (S) $2837

1910.305 B01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 11, 2025
Abate by
Jul 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to fire and electric shock hazards, in that a distribution panel did not have unused knockouts closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 11, 2025
Penalty
Initial $5,675 · Current $3,405 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.) a.) At the worksite, located at 6409 N 50th St Unit C Tampa, FL 33610; On or about 2/18/25, the employer exposed employees to fire and electric shock hazards, in that extension cords were used were used as permanent power and daisy chained together or to power strips within a spray both tent while energizing a camera, multiple light fixtures and hand powered devices in the production areas of the facility.
Recent events (2)
  • — I (S) $3405
  • — Z (S) $5675

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348046988.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.