Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIMBO QSR COLORADO, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIMBO QSR COLORADO, LLC in 4545 E 51ST AVE, DENVER, CO 80216 (NAICS 311812). OSHA activity number 348047242.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bimbo QSR Colorado, LLC — free Get an email when a new federal OSHA severe-injury report for Bimbo QSR Colorado, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4545 E 51ST AVE
City
DENVER
State
CO
ZIP
80216
Mailing
4545 E 51ST AVE, DENVER, CO 80216
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
141
Ownership type
A

5 citations on file for this inspection.

1910.29 B01

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jul 14, 2025
Penalty
Initial $16,550 · Current $11,585 Reduced
29 CFR 1910.29(b)(1): The employer did not ensure that  guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, that are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D11 of this section):  a) On or about February 18, 2025, employees in the process of dumping ingredients into the hopper/funnel of the pour deck, located at bun line 1, were potentially exposed to a fall hazard. The top rail, which measured approximately 36 inches, did not meet the medium requirement for rail heights.
Recent events (2)
  • — I (O) $11585
  • — Z (S) $16550

1910.29 B02 I

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jul 14, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails that are installed at a height midway between the top edge of the guardrail system and the walking-working surface:   a) Mixer 1: On or about February 18, 2025, the employer did not ensure that midrails were installed between the top edge and the walking working surface of the pour deck at Mixer 1. Employees were exposed to fall hazards while dumping ingredients on a pour deck.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious Gravity 1 1 instance 10 exposed
Issued
Jul 14, 2025
Penalty
Initial $7,093 · Current $4,965 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about February 17, 2022, the employer failed to conduct annual audits to evaluate the effectiveness of the company's machine specific energy control procedures  for equipment such as, but not limited to, Mixer 1 and Bun Line 1 conveyor. Energy sources used at the facility include; but are not limited to, electrical, hydraulic, and pneumatic energy.
Recent events (2)
  • — I (O) $4965.1
  • — Z (S) $7093

1910.305 G01 III

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 14, 2025
Abate by
Aug 7, 2025
Penalty
Initial $7,093 · Current $4,965 Reduced
29 CFR  1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:   (a) On or about February 18, 2025, a 12-gauge extension cord(s) was used in lieu of permanent wiring to power an industrial (floor) fan located in the oxidizer room. Employees working in the vicinity and/or the immediate area of the fan were potentially exposed to electrical hazards.
Recent events (2)
  • — I (S) $4965.1
  • — Z (S) $7093

1910.305 G02 III

Serious Gravity 1 2 instances 6 exposed
Issued
Jul 14, 2025
Abate by
Aug 7, 2025
Penalty
Initial $7,093 · Current $4,965 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   On or about February 18, 2025, employees were exposed to the following conditions:   a) Mixer 1 Control Station: The employer did not ensure that employees were protected from electrical shock hazards caused by the strain relief at the base of the mixer 1 control station box.    b) E-Stop Mixer 2: The employer did not ensure that employees were protected from shock hazards caused by exposed wires at the base of the Mixer 2 E-stop device.
Recent events (2)
  • — I (S) $4965.1
  • — Z (S) $7093

View Bimbo QSR Colorado, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348047242.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.