Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAVID H. MARTIN EXCAVATING, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAVID H. MARTIN EXCAVATING, INCORPORATED in 256 COUNTRY CLUB ROAD, CARLISLE, PA 17015 (NAICS 238910). OSHA activity number 348048844.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch David H. Martin Excavating, Incorporated — free Get an email when a new federal OSHA severe-injury report for David H. Martin Excavating, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
256 COUNTRY CLUB ROAD
City
CARLISLE
State
PA
ZIP
17015
Mailing
4961 CUMBERLAND HIGHWAY, CHAMBERSBURG, PA 17202
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.652 B01 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Feb 26, 2025
Penalty
Initial $9,045 · Current $8,000 Reduced
1926.652(b)(1)(ii)  Slopes specified in paragraph (b)(1)(i) of this section, shall be excavated to form configurations that are in accordance with the slopes shown for Type C soil in Appendix B to this subpart. 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a. Trench - On or about February 19, 2025, employees working to install a water main T-junction were in a trench greater than five feet in depth without an approved protective system such as but not limited to benching, shielding, or sloping.  Corrected During Inspection
Recent events (2)
  • — I (O) $8000
  • — Z (S) $9045

View David H. Martin Excavating, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348048844.