OSHA Inspection: BOTTEMA TILE

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BOTTEMA TILE in OTTOVILLE ROAD TAFUNA WESTERN DISTRICTA, PAGO PAGO, AS 96799 (NAICS 238340). OSHA activity number 348074535.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bottema Tile — free Get an email when a new federal OSHA severe-injury report for Bottema Tile is published. One employer, no account, unsubscribe in one click.
Establishment
BOTTEMA TILE
Site address
OTTOVILLE ROAD TAFUNA WESTERN DISTRICTA
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P. O. BOX 910811, ST GEORGE, UT 84791
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238340
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.405 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $2,837 · Current $1,986 Reduced
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  South wall: The drill used to mix the mortar was connected to an outlet with a missing cover exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $1985.9
  • — Z (S) $2837

1926.405 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.405(j)(1)(i): Fixtures, lamp holders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  South wall: The drill used to mix mortar was connected to an outlet that was not properly mounted in the box with live wiring protruding out of the socket into the room where employees were working. Employees were  exposed to electrical and fire hazards.