PAGO PAGO, AS —
OSHA Inspection: INTELLIGENT SCM LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INTELLIGENT SCM LLC in TAFUNA INDUSTRIAL PARK LE AFI ENERGY, PAGO PAGO, AS 96799 (NAICS 488510). OSHA activity number 348074600.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTELLIGENT SCM LLC
- Site address
- TAFUNA INDUSTRIAL PARK LE AFI ENERGY
- City
- PAGO PAGO
- State
- AS
- ZIP
- 96799
- Mailing
- P. O. BOX 5499, PAGO PAGO, AS 96799
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488510
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 4, 2025
- Penalty
- Initial $4,729 · Current $2,837 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees not wearing seatbelt when operating a forklift were exposed to crushed-by hazards: Warehouse floor: An employee did not use the provided manufactured restraining device while operating the forklift to move pallets in the warehouse. The employee was exposed to crushed-by and struck-by hazards.
Recent events (2)
- — I (S) $2837.4
- — Z (S) $4729
1910.178 P01
- Issued
- Apr 4, 2025
- Penalty
- Initial $2,837 · Current $1,702 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) Warehouse: A red Toyota forklift with an inoperable horn and brake light was used to load and unload pallets exposing employees to crushed-by and struck-by hazards.
Recent events (2)
- — I (S) $1702.2
- — Z (S) $2837
1910.303 B02
- Issued
- Apr 4, 2025
- Abate by
- Apr 30, 2025
- Penalty
- Initial $2,837 · Current $1,702 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Light switch near the main entrance: The galvanized switch box, intended to be mounted in a wall was installed above a metal beam to where open knockout holes on the side of the box exposed employees to electrical and fire hazards. b. Freezer southwest corner of warehouse: An orange extension cord, intended for temporary usage, was used to permanently power a freezer exposing employees to electrical and fire hazards. c. Refrigerator in the office: Power to the refrigerator was permanently supplied using an orange extension cord, intended for temporary usage, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $1702.2
- — Z (S) $2837
1910.303 B07 I
- Issued
- Apr 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. Right side, warehouse entrance: An open knockout hole on the side of the light switches galvanized box exposed employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C04
- Issued
- Apr 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition South wall: A discharged fire extinguisher was provided for incipient firefighting exposing employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Apr 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Warehouse: Fire extinguishers designated for incipient firefighting were not inspected monthly to ensure operationality and serviceability. Employees were exposed to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 X
- Issued
- Apr 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: Office: The refrigerator was placed directly on the extension cord exposing employees to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Apr 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Across from office: The outer insulation to the extension cord used to power the freezer was pulled from the plug exposing employees to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 488510)
More inspections in AS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348074600.