PENNDEL, PA —
OSHA Inspection: MOLDAMATIC, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOLDAMATIC, LLC in 29 NOELAND AVE, PENNDEL, PA 19047 (NAICS 326199). OSHA activity number 348075144.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOLDAMATIC, LLC
- Site address
- 29 NOELAND AVE
- City
- PENNDEL
- State
- PA
- ZIP
- 19047
- Mailing
- 29 NOELAND AVE, PENNDEL, PA 19047
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 10, 2025
- Abate by
- Jun 30, 2025
- Penalty
- Initial $4,788 · Current $3,591 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) 30 Noeland Ave. Penndel, PA - Tool shop - On or about February 28, 2025, the Bridgeport milling machine was not provided with machine guarding to protect operators from flying chips and sparks. b) 29 Noeland Ave. Penndel, PA - Building 1 - On or about February 28, 2025, the Bridgeport milling machine was not provided with machine guarding to protect operators from flying chips and sparks.
Recent events (2)
- — I (S) $3591
- — Z (S) $4788
1910.147 C07 IV
- Issued
- Jun 10, 2025
- Abate by
- Jun 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not provide certification that employee training was accomplished and kept up to date with the required information. b) 29 Noeland Ave. Penndel, PA - On or about February 28, 2025 the employer did not maintain lockout tagout training certification with dates and employees' names.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348075144.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.