Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOLERAS ADVANCED COATINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLERAS ADVANCED COATINGS in 589 ELM STREET, BIDDEFORD, ME 04005 (NAICS 332710). OSHA activity number 348077728.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Soleras Advanced Coatings — free Get an email when a new federal OSHA severe-injury report for Soleras Advanced Coatings is published. One employer, no account, unsubscribe in one click.
Site address
589 ELM STREET
City
BIDDEFORD
State
ME
ZIP
04005
Mailing
589 ELM STREET, BIDDEFORD, ME 04005
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
47
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 7, 2025
Abate by
May 22, 2025
Penalty
Initial $7,035 · Current $7,035
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Establishment - The employer did not perform a comprehensive periodic inspection of energy control procedures for all multi-energy source machines, spray booth plasma guns, and HEM saw annually.
Recent events (1)
  • — Z (S) $7035

1910.178 A05

Other-than-serious 1 instance 4 exposed
Issued
Apr 7, 2025
Abate by
May 22, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory-installed attachments, however, the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  Establishment - The Noblelift walk-behind forklift, fitted with a carpet boom attachment, was not equipped with a data plate containing revised capacities.
Recent events (1)
  • — Z (O) $0

1910.303 G01 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 7, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Workspace was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:  Plasma spray booth - The employer did not maintain 30 inches of space in front of electrical panel PP-6 and the associated knife switch when access was blocked by stacks of empty pails.
Recent events (1)
  • — Z (O) $0

View Soleras Advanced Coatings's full OSHA safety record →