OSHA Inspection: J & T BROTHERS, LLC

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of J & T BROTHERS, LLC in 7150 ABASSADOR DR, ALLENTOWN, PA 18106 (NAICS 238140). OSHA activity number 348077827.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & T Brothers, LLC — free Get an email when a new federal OSHA severe-injury report for J & T Brothers, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
J & T BROTHERS, LLC
Site address
7150 ABASSADOR DR
City
ALLENTOWN
State
PA
ZIP
18106
Mailing
1000 ST GEORGES AVE, AVENEL, NJ 07001
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 26, 2025
Abate by
Sep 15, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building, on or about March 3,2025, frequent and regular inspections of the job site were not conducted to ensure that hazards were addressed and eliminated to include falls from height and scaffold issues.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.451 F03

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 26, 2025
Abate by
Sep 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building: On or about March 3,2025, the in-use modular frame scaffold system was not adequately examined for defects prior to the work shift. Visible deficiencies include missing  guardrails, lack of ladders, missing cross braces, and the scaffolding not being connected to the structure.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1926.451 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 26, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building: On or about March 3,2025, employees working at a height of approximately 24 feet on a scaffold were exposed to fall hazards when working from the 4th tier of a scaffold that was not restrained from tipping by guying, tying, bracing, or equivalent means.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 26, 2025
Abate by
Sep 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building: On or about March 3,2025,  employees working  atop a scaffold at a height of approximately 24 feet above the ground without a complete guardrail systems installed along all open sides and ends.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1926.451 E01

Repeat Gravity 5 1 instance 6 exposed
Issued
Aug 26, 2025
Penalty
Initial $13,240 · Current $13,240
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access:  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building: On or about March 3,2025, employees engaged in masonry activities were exposed to fall hazards when accessing the fourth tier of the scaffold when proper access was not provided.  J&T Brothers, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1926.451(e)(1), which was contained in OSHA inspection number 1519366, citation number 4, item number 1 which was affirmed as a final order on June 15, 2022 with respect to a workplace located at 185-189 Broadway, Paterson, NJ 07505.
Recent events (2)
  • — C (R) $13240
  • — Z (R) $13240

1926.451 G01

Repeat Gravity 10 1 instance 7 exposed
Issued
Aug 26, 2025
Penalty
Initial $23,170 · Current $23,170
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building: Oon or about March 3,2025, employees engaged in masonry activities, were exposed to fall hazards of approximately 24 feet while working from scaffold platforms without any means of fall protection.  J&T Brothers, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1926.451(g)(1), which was contained in OSHA inspection number 1519366, citation number 5, item number 1 which was affirmed as a final order on June 15, 2022 with respect to a workplace located at 185-189 Broadway, Paterson, NJ 07505.
Recent events (2)
  • — C (R) $23170
  • — Z (R) $23170

1926.701 B

Other-than-serious 1 instance 1 exposed
Issued
Aug 26, 2025
Abate by
Sep 15, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement:  a) 7150 Ambassador Dr. Allentown PA, 18106. rear of building, on or about March 3,2025, employees working above unprotected rebar were exposed to impalement hazards.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

View J & T Brothers, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348077827.