RIDGELEY, WV —
OSHA Inspection: FBM SIDING PERFECTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FBM SIDING PERFECTION, LLC in ACROSS FROM 114 MEADOWLAND DR, RIDGELEY, WV 26753 (NAICS 238170). OSHA activity number 348087834.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FBM SIDING PERFECTION, LLC
- Site address
- ACROSS FROM 114 MEADOWLAND DR
- City
- RIDGELEY
- State
- WV
- ZIP
- 26753
- Mailing
- 1801 BEAVER CREEK LANE, FREDERICK, MD 21702
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 G01
- Issued
- Apr 23, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. a) Homesite 10: On or about March 6, 2025 and times prior, two employees were performing siding installation while working from a pump jack scaffold on a two-story residential structure. The scaffold platform was approximately 15 feet above ground level. The employees were not protected from falling by a guardrail system, personal fall arrest system or other approved means of fall protection, exposing them to a fall hazard of approximately 15 feet. No abatement certification or documentation is required.
Recent events (1)
- — Z (S) $4965
1926.452 J02
- Issued
- Apr 23, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Homesite 10: On or about March 6, 2025 and times prior, two employees were performing siding work from a pump jack scaffold approximately 15 feet above ground level. The pump jack poles were only secured at the top and were not braced at the bottom or other required points, exposing employees to the hazard of scaffold instability and potential collapse. No abatement certification or documentation is required.
Recent events (1)
- — Z (S) $4965
1926.451 F03
- Issued
- Apr 23, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.451(f)(3):Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) Homesite 10: On or about March 6, 2025 and times prior, a visible defect was present on the bottom of the left pump jack scaffold pole which was being used by two employees to perform siding installation approximately 15 feet above ground level. The defect had not been identified or corrected by a competent person and the scaffold was in active use at the time of inspection exposing employees to a risk of scaffold failure. No abatement certification or documentation is required.