Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AB SCAFFOLDING, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AB SCAFFOLDING, INC in 299 BEACON STREET, BOSTON, MA 02116 (NAICS 238990). OSHA activity number 348093196.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AB Scaffolding, INC — free Get an email when a new federal OSHA severe-injury report for AB Scaffolding, INC is published. One employer, no account, unsubscribe in one click.
Establishment
AB SCAFFOLDING, INC
Site address
299 BEACON STREET
City
BOSTON
State
MA
ZIP
02116
Mailing
924 WASHINGTON STREET UNIT 5, EASTON, MA 02334
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238990
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.451 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Aug 29, 2025
Penalty
Initial $5,958 · Current $5,958
29 CFR  1926.451(a)(1):Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it:Note:  Exceptions are provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section.  Location:  Jobsite at 299 Beacon Street, Boston, MA  On or about March 5, 2025 and times prior, workers were exposed to collapse and fall hazards where a scaffold, which had been wrapped with flame retardant weather protection, had not been adequately constructed to withstand the wind loads transmitted to it and collapsed under the wind load.
Recent events (1)
  • — Z (S) $5958

1926.452 C04

Serious Gravity 10 1 instance 10 exposed
Issued
Aug 29, 2025
Penalty
Initial $5,958 · Current $5,958
29 CFR  1926.452(c)(4):End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur:  Location:  Jobsite at 299 Beacon Street, Boston, MA  On or about March 5, 2025 and times prior, workers were exposed to collapse and fall hazards where a scaffold, which had been enveloped in weather protection was lacking pins connecting the end tubes of the scaffold.  High wind conditions caused the bracing to fail and uplift to occur causing the scaffold to collapse.
Recent events (1)
  • — Z (S) $5958

View AB Scaffolding, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348093196.