ROCHESTER, NY —
OSHA Inspection: POLYMER ENGINEERED PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POLYMER ENGINEERED PRODUCTS, INC. in 23 MOONLANDING ROAD, ROCHESTER, NY 14624 (NAICS 326199). OSHA activity number 348093576.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLYMER ENGINEERED PRODUCTS, INC.
- Site address
- 23 MOONLANDING ROAD
- City
- ROCHESTER
- State
- NY
- ZIP
- 14624
- Mailing
- 23 MOONLANDING ROAD, ROCHESTER, NY 14624
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 38
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II C
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $4,965 · Current $3,724 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C):The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: a) On or about 03/06/2025 throughout the establishment; where the energy control procedures did not have procedures for removal by someone other than the employee who applied the lock. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3723.75
- — Z (S) $4965
1910.147 C06 I
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $4,965 · Current $3,724 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 03/06/2025 throughout establishment; where the employer has an energy control (lockout) program but had not performed a periodic (at least annual) review of the procedures. An appropriate annual review should identify deficiencies in the written procedures. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3723.75
- — Z (S) $4965
1910.147 C06 I D
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(D):Where tagout was used for energy control, the periodic inspection did not include a review between the inspector and each authorized and affected employee of the employee's responsibilities under the energy control procedure being inspected: a) On or about 03/06/2025 throughout production areas; where the employer had not performed or documented a review, at least annually, of authorized employees performing an energy control (lockout) procedure. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $2,849 · Current $2,137 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) On or about 03/06/2025; where working space in front of electric panels in the tool storage area was used for storage of a tool cart, expandable gates, and hydraulic pump unit. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2136.75
- — Z (S) $2849
1910.37 B05
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5):Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) On or about 03/06/2025; where two doors leading into the office from the production area were not identified. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.146 C02
- Issued
- May 14, 2025
- Abate by
- Jun 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2):The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) On or about 03/06/2025; where the blender was not identified as a permit required confined space. NOTE: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Polymer Engineered Products, INC.
View Polymer Engineered Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348093576.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.