WAUSAU, WI —
OSHA Inspection: MID-CITY PRECISION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MID-CITY PRECISION, LLC in 406 WINTON STREET, WAUSAU, WI 54403 (NAICS 332710). OSHA activity number 348096975.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID-CITY PRECISION, LLC
- Site address
- 406 WINTON STREET
- City
- WAUSAU
- State
- WI
- ZIP
- 54403
- Mailing
- P.O. BOX 2194, WAUSAU, WI 54402
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 9
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.23 C08
- Issued
- Apr 18, 2025
- Abate by
- May 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(8): Portable ladders. The employer must ensure: The cap (if equipped) and top step of a stepladder are not used as steps. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Main Machining Area/Weld Area the employer failed to ensure that employees did not utilize the top step and top cap of the Kpro Keller step ladder exposing the employee to a fall hazard of approximately 46 inches. An employee used the step ladder to perform tasks and gain access to the table for the Giddings & Lewis horizontal boring machine.
Recent events (1)
- — Z (S) $0
1910.179 G01 V
- Issued
- Apr 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Main Machining Area/Weld Area; the employer did not ensure the pendant control box on the 25 Ton unidentified manufacturer overhead overhung crane had clearly marked identifiers that delineated control functions during load-hoisting operations exposing employees to struck-by and crushing hazards.
Recent events (1)
- — Z (S) $0
1910.179 J02
- Issued
- Apr 18, 2025
- Abate by
- May 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard: On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Main Machining Area/Weld Area; the employer did not conduct frequent (daily to monthly) inspections of the 25 Ton unidentified manufacturer crane used on a daily basis to move fabricated parts exposing employees to struck by and caught between hazards.
Recent events (1)
- — Z (S) $0
1910.212 A03 II
- Issued
- Apr 18, 2025
- Abate by
- May 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; Giddings & Lewis horizontal boring machine did not have point of operation guarding at the point where the cutting head met the product exposing employees to struck by, caught in between, and entanglement hazards.
Recent events (1)
- — Z (S) $0
1910.305 B01 I
- Issued
- Apr 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Main Machining Area/Weld Area; on the back side of the Giddings & Lewis horizontal boring machine was a conduit pulled exposing wires to abrasion.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Apr 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Air Compressor Room, an electrical circuit breaker panel had unused openings exposing employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Apr 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; in the Main Machining / Welding area, the Gidding & Lewis horizontal boring machine was missing the cover on the electrical terminal strip box which was used to power the rotary drill exposing employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.305 D02
- Issued
- Apr 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; Air Compressor Room, the tan 240V electrical breaker panel was missing the front cover exposing employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.332 B01
- Issued
- Apr 18, 2025
- Abate by
- May 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.332(b)(1): Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; maintenance personnel had not been trained regarding what work practices and protective equipment was required to protect them against electrical shock, arc flash, and arc blast hazards while performing diagnostic testing and verifying whether or not electrical equipment was properly de-energized.
Recent events (1)
- — Z (S) $0
1910.333 B02 I
- Issued
- Apr 18, 2025
- Abate by
- May 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(i): "Procedures." The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives. Note: The written procedures may be in the form of a copy of paragraph (b) of this section. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; the employer did not maintain documented procedures for deenergizing, locking out, and reenergizing electrical equipment. An employee was performing troubleshooting and replacement work on the Giddings & Lewis horizontal boring machine without lockout procedures exposing the employee to electrical shock hazard.
Recent events (1)
- — Z (S) $0
1910.335 A01 I
- Issued
- Apr 18, 2025
- Abate by
- May 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. Note: Personal protective equipment requirements are contained in subpart I of this part. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; an employee performing work on electrical components and fuse(s) was not provided with, or required to use, electrical personal protective equipment exposing them to burn hazards from potential arc flash.
Recent events (1)
- — Z (S) $0
1910.178 Q07
- Issued
- Apr 18, 2025
- Abate by
- May 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. On or about March 11, 2025, at an establishment located at 406 Winton Street, in Wausau, Wisconsin; the employer did not conduct daily inspections of the powered industrial vehicles on a daily basis to identify deficiencies exposing employees to struck by hazards.
Recent events (1)
- — Z (O) $0
More inspections at Mid-City Precision, LLC
View Mid-City Precision, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348096975.