Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: EDGAR ROSADOS

Programmed Other inspection · Safety discipline

On , OSHA opened a programmed Other safety inspection of EDGAR ROSADOS in 4071 NORTH 6TH STREET, MILWAUKEE, WI 53209 (NAICS 238160). OSHA activity number 348097155.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Edgar Rosados for free Get an email when a new federal OSHA severe-injury report for Edgar Rosados is published. One employer, no account, unsubscribe in one click.
Establishment
EDGAR ROSADOS
Site address
4071 NORTH 6TH STREET
City
MILWAUKEE
State
WI
ZIP
53209
Mailing
4091 NORTH 7TH STREET, MILWAUKEE, WI 53209
Inspection type
Programmed Other (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
Private (A)

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
May 1, 2025
Abate by
May 28, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  (a) On or about March 10, 2025, the employer did not ensure that the competent person was conducting frequent and regular inspections of the job site to ensure appropriate fall protection was being worn and fall protection systems were installed properly, and that ladders were installed properly.
Recent events (1)
  • · Z (S) $3547

1926.501 B11

Serious Gravity 5 1 instance 3 exposed
Issued
May 1, 2025
Penalty
Initial $3,015 · Current $3,015
29 CFR  1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  (a) On or about March 10, 2025, two employees performing tear off work on the south side of an existing residential roof with a 12:12 pitch, were using body belts in leu of full body harnesses and fall arrest system. This exposed employees to a fall hazard of approximately 25 feet from roof to the ground below.  (b) On or about March 10, 2025, an employee performing tear off work on the north side of an existing residential roof with a 12:12 pitched, was using a body belt in leu of full body harness and fall arrest system. This exposed employees to a fall hazard of approximately 25 feet from roof to the ground below.
Recent events (1)
  • · Z (S) $3015

1926.502 D17

Serious Gravity 5 1 instance 3 exposed
Issued
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(17): The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.  (a) On or about March 10, 2025, three employees performing tear off work on the south side and north side of an existing residential roof with a 12:12 pitched, were using body belts and connected the lines to the hip d-rings.
Recent events (1)
  • · Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
May 1, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On or about March 10, 2025, employees performing tear off work on an existing residential home, used two (2) Aluminum extension ladders to access the roof. The extension ladder from the balcony to the roof was not erected three (3) feet above the upper landing or secured to the structure.
Recent events (1)
  • · Z (S) $4965

1926.1053 B06

Serious Gravity 10 1 instance 3 exposed
Issued
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.   (a) On or about March 10, 2025, employees performing tear off work on an existing residential home, used an Aluminum extension ladder from the balcony to the roof that was on the slope of the gable, and which was not on a stable surface to prevent accidental displacement, exposing employees to a fall hazard.
Recent events (1)
  • · Z (S) $0

1926.503 B01

Other-than-serious 1 instance 3 exposed
Issued
May 1, 2025
Abate by
May 20, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record.  (a) On or about March 10, 2025, the employer did not verify fall protection training by preparing a written certification record when employees were trained on fall protection and the hazards associated with the work being performed.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348097155.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.