BAY CITY, TX —
OSHA Inspection: MAYEKAWA USA
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MAYEKAWA USA in 42001 FM 3057, BAY CITY, TX 77414 (NAICS 333415). OSHA activity number 348104704.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAYEKAWA USA
- Site address
- 42001 FM 3057
- City
- BAY CITY
- State
- TX
- ZIP
- 77414
- Mailing
- 29875 MEDLINE LN, KATY, TX 77494
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 180
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.120 Q01
- Issued
- Sep 4, 2025
- Abate by
- Oct 22, 2025
- Penalty
- Initial $14,895 · Current $14,895
0170
General-duty citation text
29 CFR 1910.120(q)(1): The employer, who would evacuate employees from the danger area when an emergency occurred and would not permit any employees to assist in handling the emergency, did not provide an emergency action plan in accordance with 1910.38: a) On or around March 7 2025, and at times prior thereto, the employer's emergency action plan did not specify the emergency escape procedures and emergency escape route assignments for unexpected releases of hazardous chemicals chemicals such as ammonia and experimental DOE LIMA cobalt catalyst. b) On or about March 7 2025, and times prior thereto, an employee alarm system complying with the requirements of 1910.165 was not implemented where there were unexpected releases of hazardous chemicals such as ammonia and experimental DOE LIMA cobalt catalyst.
Recent events (1)
- — Z (S) $14895
1910.134 F06
- Issued
- Sep 4, 2025
- Abate by
- Oct 22, 2025
- Penalty
- Initial $14,895 · Current $14,895
General-duty citation text
29 CFR 1910.134(f)(6): Qualitative QLFT fit tests were performed on negative pressure air-purifying respirators when the required fit factor was greater than 100: a) On or about March 7 2025, and at times prior thereto, the employer provided qualitative fit tests to employees using full face respirators such as Honeywell model RU65001 that required a fit factor of 500.
Recent events (1)
- — Z (S) $14895
1910.1200 E01 I
- Issued
- Sep 4, 2025
- Abate by
- Oct 22, 2025
- Penalty
- Initial $14,895 · Current $14,895
0170
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet: a) On or about March 7 2025, and at times prior thereto, where employees conducted commissioning operations at the -26C Ammonia refrigeration Chiller the employer did not include anhydrous ammonia or DOE LIMA catalyst as part of the known hazardous chemical list present at the workplace.
Recent events (1)
- — Z (S) $14895
1910.1200 H02 II
- Issued
- Sep 4, 2025
- Abate by
- Oct 22, 2025
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.1200(h)(2)(ii): The employer did not provide information to the employees on operations in their work area where hazardous chemicals were present: a) On or about March 7 2025, and at times prior thereto, employee training did not include the physical and health hazards of chemicals such as DOE Lima Catalyst present where employees conducted commissioning operations of the -26 C Ammonia Refrigeration Chiller.
Recent events (1)
- — Z (S) $0
More inspections at Mayekawa USA
View Mayekawa USA's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348104704.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.