OSHA Inspection: A-1 STEEL ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A-1 STEEL ERECTORS, INC. in 6650 LA HWY 44, CONVENT, LA 70723 (NAICS 238120). OSHA activity number 348105297.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A-1 Steel Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for A-1 Steel Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6650 LA HWY 44
City
CONVENT
State
LA
ZIP
70723
Mailing
3309 BARATARIA BLVD, MARRERO, LA 70072
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238120
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 8, 2025
Penalty
Initial $5,675 · Current $5,675
29 CFR  1926.453(b)(2)(v): A body belt with a lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift.  On or about March 13, 2025, at 6650 La Hwy 44, CONVENT, LA 70723, a Sheet metal roofing crew installed a metal roof from an aerial lift without fall protection.
Recent events (1)
  • — Z (S) $5675

1926.501 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 8, 2025
Penalty
Initial $6,620 · Current $6,620
29 CFR  1926.501(b)(1):"Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge that is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about March 13, 2025, the Sheet metal roofing crew installed a metal roof approximately 35 feet above the lower level without proper fall protection.
Recent events (1)
  • — Z (S) $6620

View A-1 Steel Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348105297.