CHICAGO HEIGHTS, IL —
OSHA Inspection: CHS ACQUISITION CORP.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CHS ACQUISITION CORP. in 211 E. MAIN STREET, CHICAGO HEIGHTS, IL 60411 (NAICS 331110). OSHA activity number 348109430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHS ACQUISITION CORP.
- Site address
- 211 E. MAIN STREET
- City
- CHICAGO HEIGHTS
- State
- IL
- ZIP
- 60411
- Mailing
- 211 E. MAIN STREET, CHICAGO HEIGHTS, IL 60411
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 152
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Apr 18, 2025
- Abate by
- May 14, 2025
- Penalty
- Initial $10,641 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a.) North Stud Unit - On or about March 14, 2025, employees were exposed to machine hazards associated with moving parts when engaged in the service and maintenance task of adjusting the chain on a sprocket wheel of the North Stud Unit. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10641
More inspections at CHS Acquisition Corp.
View CHS Acquisition Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 331110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348109430.