Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAGNACHARGE BATTERY USA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAGNACHARGE BATTERY USA in 647 THOMAS DRIVE, BENSENVILLE, IL 60106 (NAICS 493190). OSHA activity number 348109950.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magnacharge Battery USA — free Get an email when a new federal OSHA severe-injury report for Magnacharge Battery USA is published. One employer, no account, unsubscribe in one click.
Site address
647 THOMAS DRIVE
City
BENSENVILLE
State
IL
ZIP
60106
Mailing
647 THOMAS DRIVE, BENSENVILLE, IL 60106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.37 B06

Serious Gravity 1 3 instances 3 exposed
Issued
May 2, 2025
Abate by
May 27, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR  1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  (a) On March 14, 2025, the employer did not ensure that the Exit sign over the door in battery repair location nearest the main lobby was illuminated.  (b) On March 14, 2025, the employer did not ensure that the Exit sign over the door in the rear (east) portion of the warehouse was illuminated.  (c) On March 14, 2024, the employer did not ensure that the Exit signs along the aisleways in the warehouse were illuminated.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2837

1910.178 L01 I

Serious Gravity 5 2 instances 4 exposed
Issued
May 2, 2025
Penalty
Initial $4,729 · Current $4,729
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about March 13, 2024, at the above addressed jobsite, the employer failed to train employees on the operation of powered industrial trucks.  Employees were exposed to struck by hazards, fall hazards and improper use such the uneven loading of pallets on forks of powered industrial truck.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $4729

1910.1200 H01

Serious Gravity 5 2 instances 2 exposed
Issued
May 2, 2025
Abate by
May 27, 2025
Penalty
Initial $3,783 · Current $3,783
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   (a) Shop warehouse area - On or about March 14, 2025, employees were exposed to the corrosive chemical hazards of sulfuric acid while lifting and wrapping corroded batteries by hand without the benefit of effective hazard communication and training.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $3783

1910.1200 G01

Serious Gravity 1 1 instance 2 exposed
Issued
May 2, 2025
Abate by
May 27, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  (a) On March 14. 2025, safety data sheets were not maintained in the workplace for sulfuric acid, which can be present on used batteries.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $0

1910.303 G01 I B

Other-than-serious 1 instance 2 exposed
Issued
May 2, 2025
Abate by
May 27, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(i)(B):The width of working space in front of the electric equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the working space shall permit at least a 90-degree opening of equipment doors or hinged panels.  On or about March 14, 2025, on the west side of the building nearest the dock door of the warehouse, electrical equipment was blocked to prevent access.  Certification of abatement is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (O) $0

View Magnacharge Battery USA's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348109950.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.