Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAPOLI MARBLE & GRANITE DESIGN LTD

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NAPOLI MARBLE & GRANITE DESIGN LTD in 3501 MERRICK ROAD, SEAFORD, NY 11783 (NAICS 327991). OSHA activity number 348110883.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Napoli Marble & Granite Design LTD — free Get an email when a new federal OSHA severe-injury report for Napoli Marble & Granite Design LTD is published. One employer, no account, unsubscribe in one click.
Site address
3501 MERRICK ROAD
City
SEAFORD
State
NY
ZIP
11783
Mailing
3501 MERRICK ROAD, SEAFORD, NY 11783
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
15
Ownership type
A

9 citations on file for this inspection.

1910.134 C01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 21, 2025
Abate by
Oct 8, 2025
Penalty
Initial $2,837 · Current $2,078 Reduced
29 CFR  1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer.   a) At the Facility 3501 Merrick Road Seaford NY 11783. On or about March 14th, 2025, the employer did not establish a written respiratory protection program with worksite specific procedures for the employee who are required to wear 3M half-face tight-fitting half face  respirators when conducting stone fabrication.  Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $2078
  • — Z (S) $2837

1910.134 E01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   a) At the facility 3501 Merrick Road Seaford NY 11783. On or about  March 14th, 2025, the employer did not provide medical evaluation to employees required to wear 3M half face elastomeric respirators when performing stone fabrication.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 F02

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter:   a) At the facility 3501 Merrick Road Seaford NY 11783 .  On or about March 14th, 2025 employee(s) using tight fitting 3M half-face elastomeric respirators when performing stone fabrication were not fit tested.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 K03

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(3): The employer did not provide training prior to requiring the employee to use a respirator in the workplace.   (a) At the facility 3501  Merrick Road Seaford NY 11783. On or about March14th, 2025, the employer did not provided training to employees required to wear tight-fitting Honeywell half face elastomeric respirators while performing stone fabrication.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 E01

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Aug 21, 2025
Penalty
Initial $2,837 · Current $2,078 Reduced
29 CFR  1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200 paragraphs (f), (g), and (h) for labels and other forms of warning, safety data sheets, and employee information and training would be met.     a) At the Facility 3501 Merrick Road Seaford NY 11783. On or about March 14th, 2025, employees used chemicals such as but not limited to epoxy,  resins, and acetone which causes severe skin and throat irritations and the employer did not develop, implement and or maintain a written hazard communication program at the workplace.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (O) $2078
  • — Z (S) $2837

1910.1200 G01

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Aug 21, 2025
Abate by
Sep 16, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use  a) At the Facility 3501 Merrick Road Seaford NY 11783. On or about March 14th, 2025, the employer did not have safety data sheets in the workplace for each hazardous chemical which they used such as but not limited to epoxies, acetone, adhesives and resins during the stone fabrication.  Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 H01

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Aug 21, 2025
Abate by
Sep 16, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) At the facility 3501 Merrick Road NY 11783.  On or about March 14th, 2025, employees who use hazardous chemicals such as but not limited to epoxies, acetone, adhesives and resins were not provided with information and training on hazardous chemicals in their work area.  Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1053 D01

Other-than-serious 1 instance 8 exposed
Issued
Aug 21, 2025
Abate by
Oct 8, 2025
Penalty
Initial $398 · Current $398
29 CFR  1910.1053(d)(1): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.  a) At the facility 3501 Merrick Road Seaford NY 11783. On or about March 14th, 2025, the employer did not  assess the workplace for exposure to respirable crystalline silica  for employees engaged in stone fabrication.  Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $398
  • — Z (O) $398

1910.1053 F02 I

Other-than-serious 1 instance 8 exposed
Issued
Aug 21, 2025
Abate by
Oct 8, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1053(f)(2)(i): The employer did not establish and implement a written exposure control plan.   a) At the facility 3501 Merrick Road Seaford NY 11783. On or about March 14th, 2025, the employer did not establish and implement a written Exposure Control Plan including the description of the tasks in the workplace involving exposure to respirable crystalline silica; a description of the engineering controls, work practices, respiratory protection used to limit employee exposure to respirable crystalline silica; and a description of the housekeeping measures used to limit employee exposure to respirable crystalline silica.  Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348110883.