Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & C SIDING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & C SIDING INC. in 900 S EVERGREEN AVE, ARLINGTON HEIGHTS, IL 60005 (NAICS 238170). OSHA activity number 348112061.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & C Siding INC. — free Get an email when a new federal OSHA severe-injury report for A & C Siding INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A & C SIDING INC.
Site address
900 S EVERGREEN AVE
City
ARLINGTON HEIGHTS
State
IL
ZIP
60005
Mailing
19158 JACQUIE AVE, ROMEOVILLE, IL 60446
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.304 D

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Aug 13, 2025
Penalty
Initial $2,270 · Current $2,202 Reduced
29 CFR 1926.304(d):  Portable, power driven circular saws were not equipped with guards above and below the baseplate or shoe that automatically and instantly return to covering position when the tool is withdrawn from the work:  a) On March 14, 2025, a Makita 5007F portable circular saw being used for siding work had its lower guard tied back and failed to automatically and instantly return to its covering position.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • — I (S) $2201.85
  • — Z (S) $2270

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Aug 13, 2025
Penalty
Initial $2,838 · Current $1,929 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  a) On March 14, 2025, employees were provided with electrical tools and equipment connected by cord and plug without the use of an assured equipment grounding conductor program or ground fault circuit interrupters (GFCI's).  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1928.95
  • — Z (S) $2838

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2025
Penalty
Initial $3,972 · Current $2,185 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a) On March 14, 2025, employees were exposed to electrical hazards while erecting pump jack scaffolding in close proximity to a 120/240 volt overhead power line.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2184.6
  • — Z (S) $3972

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2025
Penalty
Initial $3,972 · Current $2,185 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:  a) On  March 14, 2025, employees working from pump jack scaffolding were exposed to fall hazards of approximately 13.1 feet.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2184.6
  • — Z (S) $3972

1926.454 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Aug 22, 2025
Penalty
Initial $2,838 · Current $0 Reduced
29 CFR  1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area.  a) On or about March 14, 2025, employees were exposed to electrical and fall hazards while erecting and working from a pump jack scaffold. The employer did not provide a training program to recognize the hazards and the procedures associated with scaffolding work in order to minimize those hazards.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2838

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348112061.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.