OSHA Inspection: AMERICOLD LOGISTICS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICOLD LOGISTICS, LLC in 3800 HEMPLAND ROAD, MOUNTVILLE, PA 17554 (NAICS 493120). OSHA activity number 348116872.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Americold Logistics, LLC — free Get an email when a new federal OSHA severe-injury report for Americold Logistics, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3800 HEMPLAND ROAD
City
MOUNTVILLE
State
PA
ZIP
17554
Mailing
3800 HEMPLAND ROAD SUITE 2, MOUNTVILLE, PA 17554
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
493120
Employees
90
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 4 instances 5 exposed
Issued
Sep 3, 2025
Abate by
Sep 17, 2025
Penalty
Initial $11,348 · Current $11,348
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  a. Penthouse 1 - On or about April 24, 2025, the only door leading out of the penthouse was not marked with an "exit" sign to guide employees out of the room in the event of emergency, employees were exposed to hazards associated with delayed egress such as fire and ammonia exposures.  b. Penthouse 2 - On or about April 24, 2025, the only door leading out of the penthouse was not marked with an "exit" sign to guide employees out of the room in the event of emergency, employees were exposed to hazards associated with delayed egress such as fire and ammonia exposures.  c. Penthouse 3 - On or about April 24, 2025, the only door leading out of the penthouse was not marked with an "exit" sign to guide employees out of the room in the event of emergency, employees were exposed to hazards associated with delayed egress such as fire and ammonia exposures.  d. Penthouse 4 - On or about April 24, 2025, the only door leading out of the penthouse was not marked with an "exit" sign to guide employees out of the room in the event of emergency, employees were exposed to hazards associated with delayed egress such as fire and ammonia exposures.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — C (S) $11348
  • — Z (S) $11348

1910.110 F02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 3, 2025
Penalty
Initial $11,348 · Current $11,348
29 CFR  1910.110(f)(2)(ii): The employer did not ensure all liquefied petroleum gas container stored inside were located away from exits, stairways, or in areas normally used or intended for the safe exit of people.  a. Ammonia room discharge ramp - On or about March 19, 2025, the employer was storing four tanks of LPG on the exit discharge ramp for the ammonia system engine room and electrical control room.    Corrected During Inspection
Recent events (2)
  • — C (S) $11348
  • — Z (S) $11348

1910.119 D03 II

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 3, 2025
Abate by
Oct 8, 2025
Penalty
Initial $16,550 · Current $16,550

Hazardous substances 0170

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.  a. Outside the Engine Room - On or about March 19, 2025, the employer did not document that equipment complies with employer's chosen RAGAGEP IIAR 2-2014: Section 6.12.2 Emergency Ventilation Control when an emergency ventilation control switch for activation of emergency ventilation was not located outside the machinery room door. Failure to install an activation switch can result in employees being exposed to high levels of ammonia in the event of a release.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (S) $16550
  • — Z (S) $16550

1910.119 J04 II

Serious Gravity 5 3 instances 5 exposed
Issued
Sep 3, 2025
Abate by
Oct 8, 2025
Penalty
Initial $13,005 · Current $13,005

Hazardous substances 0170

29 CFR  1910.119(j)(4)(ii): The inspection and testing procedures did not follow recognized and generally accepted good engineering practices    a. Engine Room - On or about March 19, 2025, the employer failed to establish and implement inspection and testing procedures that follow their chosen RAGAGEP, such as but not limited to IIAR 6-2019 Standard for Inspection, Testing and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Chapter 13 when they failed to replace or recertify the Parker relief valve, #CKR4T7RW, on the thermosyphon associated with the Compressor Package within the required five-year cycle.  Failure to maintain pressure relief devices according to RAGAGEP standards may result in these devices failing during emergencies. This could potentially lead to over-pressurization, explosions, and expose the employees to released anhydrous ammonia.  b. Engine Room - On or about March 19, 2025, the employer failed to establish and implement inspection and testing procedures that follow their chosen RAGAGEP, such as but not limited to IIAR 6-2019 Standard for Inspection, Testing and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Chapter 13 when they failed to replace or recertify the Parker relief valve I2EXZ2SX on the intercooler associated with the Compressor Package within the required five-year cycle. Failure to maintain pressure relief devices according to RAGAGEP standards may result in these devices failing during emergencies. This could potentially lead to over-pressurization, explosions, and expose the employees to released anhydrous ammonia.  c. Engine Room - On or about March 19, 2025, the employer failed to establish and implement inspection and testing procedures that follow their chosen RAGAGEP, such as but not limited to IIAR 6-2019 Standard for Inspection, Testing and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Chapter 13 when they failed to replace or recertify the Parker relief valve H3681QQ3 on the heat exchanger associated with the Compressor Package 1 within the required five-year cycle. Failure to maintain pressure relief devices in accordance with RAGAGEP can result in the failure of the relief device in the event of an emergency resulting in over pressurization, explosion and release of anhydrous ammonia.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — C (S) $13005
  • — Z (S) $13005

1910.305 B02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 3, 2025
Penalty
Initial $8,512 · Current $8,512
29 CFR  1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a. Engine Room - On or about March 19, 2025, employees were exposed to a shock hazard due to the junction box attached to the Auto-Purger control dial box was missing its cover with voltage in excess of 50 volts AC.  Corrected During Inspection
Recent events (2)
  • — C (S) $8512
  • — Z (S) $8512

View Americold Logistics, LLC's full OSHA safety record →