OSHA Inspection: RAFSA CONSTRUCTION INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RAFSA CONSTRUCTION INC in 2820 VETERANS BLVD, DEL RIO, TX 78840 (NAICS 238190). OSHA activity number 348116922.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rafsa Construction INC — free Get an email when a new federal OSHA severe-injury report for Rafsa Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
2820 VETERANS BLVD
City
DEL RIO
State
TX
ZIP
78840
Mailing
1575 SUNBEAM RIDGE RD, EAGLE PASS, TX 78852
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
6
Ownership type
A

12 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2025
Abate by
Jun 26, 2025
Penalty
Initial $4,256 · Current $2,128 Reduced
29 CFR  1926.451(a)(6):Scaffolds were not constructed in accordance with the design by a qualified person.  On or about March 13, 2025, in the new service shop, employees worked on scaffolds that was not constructed in accordance with the design of a qualified person while erecting a new wall with CMU blocks.
Recent events (2)
  • — I (S) $2128
  • — Z (S) $4256

1926.451 B01

Serious Gravity 5 8 instances 6 exposed
Issued
May 30, 2025
Penalty
Initial $2,837 · Current $1,419 Reduced
29 CFR  1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  On or about March 13, 2025, in the new service shop, employees  worked on scaffolds that were not fully planked while erecting a new wall with Concrete blocks.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.451 B01 I

Serious Gravity 5 8 instances 6 exposed
Issued
May 30, 2025
Abate by
Jun 26, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  On or about March 13, 2025, in the new service shop, employees worked on a scaffold while erecting a new wall with CMU blocks and the space between the platform and the uprights were more than 1 inch wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B05 II

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2025
Penalty
Initial $2,837 · Current $1,419 Reduced
29 CFR  1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.  On or about March 13, 2025, in the new service shop, employees walked and worked on scaffolds where the platform extended 2 feet beyond where the support was installed.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.451 C02

Serious Gravity 5 18 instances 6 exposed
Issued
May 30, 2025
Abate by
Jun 26, 2025
Penalty
Initial $4,256 · Current $2,128 Reduced
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation.  On or about March 13, 2025, in the new service shop, employees were utilizing a scaffold that with missing base plates while installing a newly constructed CMU wall.
Recent events (2)
  • — I (S) $2128
  • — Z (S) $4256

1926.451 E01

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2025
Penalty
Initial $2,837 · Current $1,419 Reduced
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.  On or about March 13, 2025, in the new service shop, workers used the cross braces of a scaffold to reach their work area to do masonry work.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.451 F06

Serious Gravity 10 3 instances 6 exposed
Issued
May 30, 2025
Penalty
Initial $4,965 · Current $2,483 Reduced
29 CFR  1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  On or about March 13, 2025, in the new service shop, employees walked and worked on a scaffold while erecting a new wall with CMU blocks that was approximately 6 feet from an energized overhead power line.
Recent events (2)
  • — I (S) $2482.5
  • — Z (S) $4965

1926.451 F07

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2025
Penalty
Initial $2,837 · Current $1,419 Reduced
29 CFR  1926.451(f)(7):Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  On or about March 13, 2025, in the new service shop, employees were erecting a new wall with CMU blocks from the third tier of a scaffold that was moved and erected several times without a competent person qualified in scaffold erection.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.451 G01

Serious Gravity 10 1 instance 6 exposed
Issued
May 30, 2025
Penalty
Initial $4,965 · Current $2,483 Reduced
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:  On or about March 13, 2025, in the new service shop, employees were walking and working on a scaffold at heights above 10 feet while erecting a new wall with CMU blocks without fall protection.
Recent events (2)
  • — I (S) $2482.5
  • — Z (S) $4965

1926.451 H01

Serious Gravity 5 10 instances 6 exposed
Issued
May 30, 2025
Penalty
Initial $2,837 · Current $1,419 Reduced
29 CFR  1926.451(h)(1):Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall.  On or about March 13, 2025, in the new service shop, employees were walking and working on the second tier of a scaffold that did not have toe boards installed while CMU blocks were stored on the third tier.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.452 A02

Serious Gravity 10 6 instances 6 exposed
Issued
May 30, 2025
Abate by
Jun 26, 2025
Penalty
Initial $4,965 · Current $2,483 Reduced
29 CFR  1926.452(a)(2): Crossbracing shall be installed between the inner and outer sets of poles on double pole scaffolds.  On or about March 13, 2025, in the new service shop, employees worked on a scaffold that was missing crossbracing at several locations and tiers while erecting a new wall with CMU blocks.
Recent events (2)
  • — I (S) $2482.5
  • — Z (S) $4965

1926.454 A

Serious Gravity 1 1 instance 6 exposed
Issued
May 30, 2025
Abate by
Jun 26, 2025
Penalty
Initial $2,128 · Current $1,064 Reduced
29 CFR  1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  On or about March 13, 2025, in the new service shop, employees were not trained in the recognition of hazards associated while working on a scaffold while erecting a new wall with CMU blocks.
Recent events (2)
  • — I (S) $1064
  • — Z (S) $2128