Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RURAL SOLAR RESTORATION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RURAL SOLAR RESTORATION, LLC in 12907 FM 361, RICHMOND, TX 77469 (NAICS 811310). OSHA activity number 348120171.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rural Solar Restoration, LLC — free Get an email when a new federal OSHA severe-injury report for Rural Solar Restoration, LLC is published. One employer, no account, unsubscribe in one click.
Site address
12907 FM 361
City
RICHMOND
State
TX
ZIP
77469
Mailing
3527 QUITMAN ST, DENVER, CO 80212
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
2
Ownership type
A

3 citations on file for this inspection.

1910.269 A02 I A

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Jul 29, 2025
Penalty
Initial $9,268 · Current $4,634 Reduced
29 CFR  1910.269(a)(2)(i)(A): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.   a) On or about March 15, 2025, and times prior to, at the jobsite, an employee was not trained in electrical hazard recognition before accessing a combiner box to test for a fault.
Recent events (2)
  • — I (O) $4634
  • — Z (S) $9268

1910.269 D06 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Jul 29, 2025
Penalty
Initial $9,268 · Current $4,634 Reduced
29 CFR  1910.269(d)(6)(vii):  Before starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergizing of the machine or equipment had been accomplished.  a) On March 15, 2025, at the jobsite, a solar panel combiner box was not isolated or de-energized while an employee was assessing a circuit fault.
Recent events (2)
  • — I (S) $4634
  • — Z (S) $9268

1910.269 L08 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Jul 29, 2025
Penalty
Initial $7,945 · Current $0 Reduced
29 CFR  1910.269(l)(8)(v): The employer did not ensure that each employee exposed to hazards from electric arcs wore protective clothing and other protective equipment that had an arc rating greater than or equal to the heat energy estimated under paragraph (l)(8)(ii) of this section whenever that estimate exceeded 2.0 Cal/cm2.:    a) On March 15, 2025, at the jobsite while testing an electrically energized solar panel combiner box for continuity, an employee was not wearing a flame-resistant shirt while testing for a circuit fault.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7945

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348120171.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.