BILLERICA, MA —
OSHA Inspection: T FORCE FREIGHT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of T FORCE FREIGHT in 35 DUNHAM STREET, BILLERICA, MA 01821 (NAICS 541614). OSHA activity number 348122086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T FORCE FREIGHT
- Site address
- 35 DUNHAM STREET
- City
- BILLERICA
- State
- MA
- ZIP
- 01821
- Mailing
- 35 DUNHAM STREET, BILLERICA, MA 01821
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541614
- Employees
- 39
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 A03
- Issued
- Jun 11, 2025
- Abate by
- Jul 1, 2025
- Penalty
- Initial $9,457 · Current $6,620 Reduced
General-duty citation text
29 CFR 1910.37(a)(3):Exit route(s) were not kept free and unobstructed. Location - Storage Area: On or about 03/20/2025, The employer did not maintain the minimum width requirement for an exit route at all points, an object projected into the exit route.
Recent events (2)
- — I (S) $6619.9
- — Z (S) $9457
1910.178 F02
- Issued
- Jun 11, 2025
- Abate by
- Jul 1, 2025
- Penalty
- Initial $9,457 · Current $6,620 Reduced
General-duty citation text
29 CFR 1910.178(f)(2):29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA No. 58-1969, Storage and Handling of Liquefied Petroleum Gases. Section 6.21.3.4(B): Fuel containers shall be mounted to prevent jarring loose and slipping or rotating, and the fastening shall be designed and constructed to withstand, without permanent visible deformation, static loading in any direction equal to four times the weight of the container filled with fuel. Location - Exit Area On or about 03/20/2025, the employer was storing flammables outside an exit.
Recent events (2)
- — I (S) $6619.9
- — Z (S) $9457
1910.303 G01 I
- Issued
- Jun 11, 2025
- Abate by
- Jul 1, 2025
- Penalty
- Initial $9,457 · Current $6,620 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i):The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1. Location - Storage Area: On or about 03/20/2025, The employer did not maintain a 30-inch wide clearance in front of an electrical box. The electrical panel was block by stored boxes.
Recent events (2)
- — I (S) $6619.9
- — Z (S) $9457
More inspections at T Force Freight
View T Force Freight's full OSHA safety record →
More inspections in this industry (NAICS 541614)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348122086.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.