SAN ANTONIO, TX —
OSHA Inspection: SANCHEZ CONTRACTORS, LLC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SANCHEZ CONTRACTORS, LLC. in 2707 WILD SKIES, SAN ANTONIO, TX 78245 (NAICS 236116). OSHA activity number 348125386.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANCHEZ CONTRACTORS, LLC.
- Site address
- 2707 WILD SKIES
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78245
- Mailing
- 16497 WISDOM RD., ATASCOSA, TX 78002
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 A06
- Issued
- Jun 3, 2025
- Penalty
- Initial $2,128 · Current $2,128
General-duty citation text
29 CFR 1926.451(a)(6):Scaffolds were not constructed in accordance with the design by a qualified person. On or about March 21, 2025, and at times prior thereto, employees were utilizing scaffolding to apply stucco to a two-story residential building that was not constructed in accordance with the design of a qualified person.
Recent events (1)
- — Z (S) $2128
1926.451 B01 I
- Issued
- Jun 3, 2025
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. On or about March 21, 2025, and at times prior thereto, employees were utilizing scaffolding to apply stucco to a two-story residential building with planking not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide.
Recent events (1)
- — Z (S) $2837
1926.451 C02
- Issued
- Jun 3, 2025
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about March 21, 2025, and at times prior thereto, employees were utilizing scaffolding to apply stucco to a two-story residential with missing base plates and mud sills.
Recent events (1)
- — Z (S) $2837
1926.451 G01
- Issued
- Jun 3, 2025
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. On or about March 21, 2025, and at times prior thereto, employees were utilizing scaffolding to apply stucco to a two-story residential building at heights above 10 feet without utilizing fall protection.
Recent events (1)
- — Z (S) $2837
More inspections in this industry (NAICS 236116)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348125386.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.