REVERE, MA —
OSHA Inspection: BOSTON PANEL SYSTEMS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOSTON PANEL SYSTEMS in 93 BENNINGTON ST., REVERE, MA 02151 (NAICS 238170). OSHA activity number 348126152.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOSTON PANEL SYSTEMS
- Site address
- 93 BENNINGTON ST.
- City
- REVERE
- State
- MA
- ZIP
- 02151
- Mailing
- 15 ERIE DRIVE, NATICK, MA 01760
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 2, 2025
- Abate by
- Sep 10, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2):The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person. LOCATION: The worksite at 93 Bennington St., Revere a) Two lanyards were connected together and to the D-ring on the employee's harness in stead of a vertical lifeline. b) The Personal Fall Protection System, as it was being used, would not have been capable of supporting at least 5,000 pounds (22.2 kN) per employee. c) The anchorages used for attachment of personal fall arrest systems were not designed, installed and used under the supervision of a qualified person. d) Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and a visibly defective lanyard was not removed from service. e) A worker was observed standing on the mid-rail of a Mobile Elevated Work Platform (MEWP) without a restraining belt or other personal fall arrest system in place. On or about April 10, 2025, the employer exposed their workers to numerous hazards when no competent person was on site to prevent unsafe practices as part of a safety program that provided for frequent and regular inspections.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1926.416 A01
- Issued
- Sep 2, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1926.416(a)(1):The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work. LOCATION: The worksite at 93 Bennington St., Revere On or about March 20, 2025, the employees were exposed to burn and electrocution hazards when the employer allowed the workers to operate the baskets of the aerial lifts within 10 feet of the high voltage power lines.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
More inspections in this industry (NAICS 238170)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348126152.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.