OSHA Inspection: BOSTON PANEL SYSTEMS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BOSTON PANEL SYSTEMS in 93 BENNINGTON ST., REVERE, MA 02151 (NAICS 238170). OSHA activity number 348126152.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boston Panel Systems — free Get an email when a new federal OSHA severe-injury report for Boston Panel Systems is published. One employer, no account, unsubscribe in one click.
Site address
93 BENNINGTON ST.
City
REVERE
State
MA
ZIP
02151
Mailing
15 ERIE DRIVE, NATICK, MA 01760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 10 1 instance 13 exposed
Issued
Sep 2, 2025
Abate by
Sep 10, 2025
Penalty
Initial $6,620 · Current $0 Reduced
29 CFR  1926.20(b)(2):The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person.  LOCATION: The worksite at 93 Bennington St., Revere  a) Two lanyards were connected together and to the D-ring on the employee's harness in stead of a vertical lifeline.  b) The Personal Fall Protection System, as it was being used, would not have been capable of supporting at least 5,000 pounds (22.2 kN) per employee.  c) The anchorages used for attachment of personal fall arrest systems were not designed, installed and used under the supervision of a qualified person.  d) Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and a visibly defective lanyard was not removed from service.  e) A worker was observed standing on the mid-rail of a Mobile Elevated Work Platform (MEWP) without a restraining belt or other personal fall arrest system in place.   On or about  April 10, 2025, the employer exposed their workers to numerous hazards when no competent person was on site to prevent unsafe practices as part of a safety program that provided for frequent and regular inspections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6620

1926.416 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2025
Penalty
Initial $6,620 · Current $0 Reduced
29 CFR  1926.416(a)(1):The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work.  LOCATION: The worksite at 93 Bennington St., Revere  On or about March 20, 2025, the employees were exposed to burn and electrocution hazards when the employer allowed the workers to operate the baskets of the aerial lifts within 10 feet of the high voltage power lines.