FAIRFIELD, OH —
OSHA Inspection: BOGGESS ELECTRIC INC.,
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOGGESS ELECTRIC INC., in 4785 DIXIE HWY, FAIRFIELD, OH 45014 (NAICS 238210). OSHA activity number 348128794.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOGGESS ELECTRIC INC.,
- Site address
- 4785 DIXIE HWY
- City
- FAIRFIELD
- State
- OH
- ZIP
- 45014
- Mailing
- 1240 GLENDALE MILFORD BLDG 13, CINCINNATI, OH 45215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.405 B02
- Issued
- Jun 18, 2025
- Abate by
- Jul 24, 2025
- Penalty
- Initial $5,958 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.405(b)(2):Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a.)On or about March 24, 2025, the employer failed to ensure that energized junction boxes located on the ground level and the second level of a gut-rehab building were provided with covers. As a result, employees installing new wiring and making electrical connections were exposed to 208-volt electrocution hazards.
Recent events (2)
- — I (O) $2000
- — Z (S) $5958
1926.416 A01
- Issued
- Jun 18, 2025
- Abate by
- Jul 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. a.) On or about March 24, 2025, the employer failed to ensure that employees working in proximity to live electrical junction box were protected from electric shock by deenergizing and grounding the circuit, or by effectively guarding it through insulation or maintaining a safe working distance. As a result, employees were exposed to electric shock hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.416 B01
- Issued
- Jun 18, 2025
- Abate by
- Jul 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(b)(1): Barriers or other means of guarding shall be provided to ensure that workspace for electrical equipment will not be used as a passageway during periods when energized parts of electrical equipment are exposed. a) On or about March 24, 2025, the employer failed to provide barriers or other means of guarding to prevent the use of workspaces containing exposed energized electrical components as passageways on the ground level and second level of a gut-rehab building. As a result, employees installing new wiring and making electrical connections were exposed to electrocution hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.960 G01
- Issued
- Jun 18, 2025
- Abate by
- Jul 24, 2025
- Penalty
- Initial $5,958 · Current $0 Reduced
General-duty citation text
29 CFR 1926.960(g)(1): Hazard assessment. The employer shall assess the workplace to identify employees exposed to hazards from flames or from electric arcs. a.) On or about March 24, 2025, the employer failed to conduct a hazard assessment of the workplace and identify missing covers and canopies for live-active junction boxes located on the ground level, and the second level of a gut-rehab building, live electrical junction boxes were deenergized and grounded or guarded effectively by insulation or by ensuring employees worked at a safe proximity , ,in that the employer exposed employees to electrocution hazards of 208V, from power coming into the building from outside pole, as employees installed new wiring, and connections within a new junction box.
Recent events (2)
- — I (O) $0
- — Z (S) $5958
1926.20 B02
- Issued
- Jun 18, 2025
- Abate by
- Jul 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. a) On or about March 24, 2025, the employer failed to conduct frequent and regular inspections of the jobsite by a competent person to identify hazards, including missing covers on energized junction boxes and the lack of guarding or deenergization of live electrical components. As a result, employees working on the ground and second levels of a gut-rehab building were exposed to 208-volt electrocution hazards while installing new wiring and making electrical connections in energized junction boxes.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Boggess Electric INC.,