Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EDSAL MANUFACTURING COMPANY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EDSAL MANUFACTURING COMPANY, LLC in 1555 W. 44TH STREET, CHICAGO, IL 60609 (NAICS 337124). OSHA activity number 348135831.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Edsal Manufacturing Company, LLC — free Get an email when a new federal OSHA severe-injury report for Edsal Manufacturing Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1555 W. 44TH STREET
City
CHICAGO
State
IL
ZIP
60609
Mailing
4400 S. PACKERS AVENUE, CHICAGO, IL 60609
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337124
Employees
378
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 9, 2025
Abate by
Jul 7, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Production - On or about March 18, 2025, and days prior to, authorized employees were required to perform servicing and/or maintenance on the Morrill and Moeller ovens, Midwest Mixing mixers, Morrill and Moeller washers, Dayton exhaust fans, and other operating equipment. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (1)
  • — Z (S) $16550

1910.147 C07 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 9, 2025
Abate by
Jul 7, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  a) Rooftop - On March 18, 2025, an employees performed the service and maintenance task of inspecting an exhaust fan belt.  The employer failed to ensure that employees who perform service and/or maintenance received training in the energy control program, and recognition of applicable hazardous energy sources, the types and magnitude of the energy available in the workplace and the methods and means necessary for energy isolation and control, thereby exposing employees to the unexpected energization and/or startup of the equipment.
Recent events (1)
  • — Z (S) $16550

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 9, 2025
Abate by
Jul 7, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) Rooftop - On or about March 19, 2025, an employee sustained a left middle fingertip amputation when a second employee performed service and maintenance on an exhaust fan unit.   The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
  • — Z (S) $16550

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 9, 2025
Abate by
Jul 7, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a.) Roof - On or about March 26, 2025, the employer failed to provide effective guarding to protect employees working at or near an exhaust fan.  Power was restored to an exhaust fan unit while an employee inspected the belt's installation, causing a middle fingertip amputation.
Recent events (1)
  • — Z (S) $16550

View Edsal Manufacturing Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348135831.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.