Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BORGZINNER INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BORGZINNER INC. in 1160 WEST 13TH ST, UNIT 10, RIVIERA BEACH, FL 33404 (NAICS 337110). OSHA activity number 348137035.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Borgzinner INC. — free Get an email when a new federal OSHA severe-injury report for Borgzinner INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BORGZINNER INC.
Site address
1160 WEST 13TH ST, UNIT 10
City
RIVIERA BEACH
State
FL
ZIP
33404
Mailing
1160 WEST 13TH ST, UNIT 10, RIVIERA BEACH, FL 33404
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
33
Ownership type
A

7 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 24, 2025
Abate by
Jul 21, 2025
Penalty
Initial $11,585 · Current $5,793 Reduced
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:  On or about 3/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, combustible dust exceeded 5% and 3/4-inch in depth in one area and was prevalent throughout the facility, thus exposing employees to a fire ad explosion hazards.
Recent events (2)
  • — I (S) $5793
  • — Z (S) $11585

1910.107 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2025
Abate by
Jul 21, 2025
Penalty
Initial $6,620 · Current $3,310 Reduced
29 CFR  1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:   On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, combustible materials (wood) was stored within 3 feet of a paint booth, thus exposing employees to fire or explosion hazards while using the paint booth where flammable liquids were used.
Recent events (2)
  • — I (S) $3310
  • — Z (S) $6620

1910.107 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2025
Penalty
Initial $6,620 · Current $3,310 Reduced
29 CFR  1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:   On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, flammable liquids were allowed to accumulate on the walls of the paint booth, thus exposing employees to fire and/or explosion hazards while using the paint booth.
Recent events (2)
  • — I (S) $3310
  • — Z (S) $6620

1910.303 G01 I C

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2025
Abate by
Jul 21, 2025
Penalty
Initial $6,620 · Current $3,310 Reduced
29 CFR  1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303:   On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, the width of workspace was not clear of combustible materials (wooden boards) in front of electrical boxes (220 volts nominal), thus exposing employees to a fire hazards.
Recent events (2)
  • — I (S) $3310
  • — Z (S) $6620

1910.307 C

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 24, 2025
Abate by
Jul 21, 2025
Penalty
Initial $11,585 · Current $5,793 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, employees were exposed to fire and explosion hazards while working in a Class II, Division 1 location, where electrical equipment installed (fans, microwaves, and vacuums) was not intrinsically safe, approved, or made safe for use in this type of location.
Recent events (2)
  • — I (S) $5793
  • — Z (S) $11585

1904.41 A01 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 24, 2025
Abate by
Jul 21, 2025
Penalty
Initial $1,655 · Current $828 Reduced
29 CFR 1904.41(a)(1)(i): If your establishment had 20-249 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form:  On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, OSHA Form 300A of Work-Related Injuries and Illnesses were not submitted to OSHA or OSHA's designee by March 2, 2025, as required in paragraph (c).
Recent events (2)
  • — I (O) $828
  • — Z (O) $1655

1910.303 C03 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 24, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy.   Soldered splices were not spliced or joined mechanically and electrically secured first without solder and then soldered.  All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:  On or about 03/26/2025, at 1160 West 13th Street, Unit 10, Riviera Beach, Florida, an extension cord was spliced with electrical tape, thus exposing employees to potential electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Borgzinner INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348137035.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.