TEMPLE, PA —
OSHA Inspection: COBRA ANCHORS CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COBRA ANCHORS CORPORATION in 504 MT LAUREL AVENUE, TEMPLE, PA 19560 (NAICS 332510). OSHA activity number 348141169.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COBRA ANCHORS CORPORATION
- Site address
- 504 MT LAUREL AVENUE
- City
- TEMPLE
- State
- PA
- ZIP
- 19560
- Mailing
- 504 MT LAUREL AVENUE, TEMPLE, PA 19560
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 86
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 5, 2025
- Abate by
- Sep 22, 2025
- Penalty
- Initial $9,457 · Current $7,093 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) 504 Mt Laurel Avenue, Temple - Clipping Department - On or about March 27, 2025, the employer did not conduct an annual or more frequent inspection of the energy control procedures utilized in the control of hazardous energy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $7093
- — Z (S) $9457
1910.147 C07 I B
- Issued
- Aug 5, 2025
- Abate by
- Sep 22, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employee(s) was not instructed in the purpose and use of the energy control procedure. a) 504 Mt Laurel Avenue, Temple - Clipping Department - On or about March 27, 2025, affected employees were not instructed in the purpose and use of energy control procedures. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Cobra Anchors Corporation
View Cobra Anchors Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332510)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348141169.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.