Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAPID FOUNDATION REPAIR, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RAPID FOUNDATION REPAIR, INC. in 1124 NORTH 7TH STREET, RAPID CITY, SD 57701 (NAICS 238190). OSHA activity number 348143421.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rapid Foundation Repair, INC. — free Get an email when a new federal OSHA severe-injury report for Rapid Foundation Repair, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1124 NORTH 7TH STREET
City
RAPID CITY
State
SD
ZIP
57701
Mailing
2601 HAINES AVENUE, RAPID CITY, SD 57701
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
11
Ownership type
A

5 citations on file for this inspection.

1926.651 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 27, 2025
Abate by
Jul 30, 2025
Penalty
Initial $6,242 · Current $3,121 Reduced
29 CFR  1926.651(k)(1):Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:   (a)Rapid Foundation Repair, Inc. at 1124 North 7th Street, Rapid City, SD 57701: On or about and at times prior to March 28, 2025, the employer did not ensure a competent person conducted daily inspections to include both visual and manual evaluation to aid in classifying soil type prior to employees performing work in the excavations. This condition exposed employees to struck-by and cave-in hazards.
Recent events (2)
  • — I (S) $3121
  • — Z (S) $6242

1926.1153 D02 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2025
Abate by
Jul 30, 2025
Penalty
Initial $4,161 · Current $2,081 Reduced
29 CFR  1926.1153(d)(2)(i):The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section:  (a)Rapid Foundation Repair, Inc. at 1124 North 7th Street, Rapid City, SD 57701: On or about and at times prior to March 28, 2025, the employer did not ensure employees were protected from health hazards of occupational exposure to respirable crystalline silica when operating a Bosch Demolition Hammer to remove portions of concrete from residential foundations in that the employer did not implement controls specified in Table 1 or assess employee exposure to respirable crystalline silica. Employees who inhale respirable crystalline silica are at an increased risk of developing serious disease including but not limited to; silicosis, lung cancer, chronic obstructive pulmonary disease and kidney cancer.
Recent events (2)
  • — I (O) $2080.5
  • — Z (S) $4161

1926.652 A01

Repeat Gravity 10 1 instance 3 exposed
Issued
Jun 27, 2025
Abate by
Jul 30, 2025
Penalty
Initial $14,564 · Current $7,282 Reduced
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  (a)Rapid Foundation Repair, Inc. at 1124 North 7th Street, Rapid City, SD 57701: On or about and at times prior to March 28, 2025,  the employer did not ensure adequate protective systems were used when employees performed work in excavations deeper than five feet. This condition exposed employees to struck-by and cave-in hazards.  Rapid Foundation Repair, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1727989, citation number 1, item number 4 and was affirmed as a final order on 6/10/2024, with respect to a workplace located at 514 Washington Street, Lead, SD 57754.
Recent events (2)
  • — I (R) $7282
  • — Z (R) $14564

1926.651 C02

Repeat Gravity 10 1 instance 3 exposed
Issued
Jun 27, 2025
Abate by
Jul 30, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a)Rapid Foundation Repair, Inc. at 1124 North 7th Street, Rapid City, SD 57701: On or about and at times prior to March 28, 2025,  the employer did not ensure a safe means of egress was located in excavations 4 feet or more in depth to allow safe access and egress. This condition exposed employees to struck-by and cave-in hazards.   Rapid Foundation Repair, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1727989, citation number 1, item number 3a and was affirmed as a final order on 6/10/2024, with respect to a workplace located at 514 Washington Street, Lead, SD 57754.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1926.651 J02

Repeat Gravity 10 1 instance 3 exposed
Issued
Jun 27, 2025
Abate by
Jul 30, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  (a)Rapid Foundation Repair, Inc. at 1124 North 7th Street, Rapid City, SD 57701: On or about and at times prior to March 28, 2025, the employer did not ensure spoils piles were located at least 2 feet from the edge of excavations. This condition exposed employees to cave-in and struck-by hazards.  Rapid Foundation Repair, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1727989, citation number 1, item number 3b and was affirmed as a final order on 6/10/2024, with respect to a workplace located at 514 Washington Street, Lead, SD 57754.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Rapid Foundation Repair, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348143421.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.