BIRMINGHAM, AL —
OSHA Inspection: PINSON VALLEY FABRICATORS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PINSON VALLEY FABRICATORS, INC. in 4440 PINSON VALLEY PARKWAY, BIRMINGHAM, AL 35215 (NAICS 332312). OSHA activity number 348154030.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PINSON VALLEY FABRICATORS, INC.
- Site address
- 4440 PINSON VALLEY PARKWAY
- City
- BIRMINGHAM
- State
- AL
- ZIP
- 35215
- Mailing
- P. O. BOX 369, PINSON, AL 35126
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 D01
- Issued
- Aug 27, 2025
- Penalty
- Initial $2,553 · Current $1,532 Reduced
General-duty citation text
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) On or about April 3, 2025, on the south side of the work area, the southwest exit door was locked, preventing employees from being able to safely egress from the work area in an emergency.
Recent events (2)
- — I (S) $1531.8
- — Z (S) $2553
1910.37 A03
- Issued
- Aug 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) On or about April 3, 2025, throughout the work area, items such as cords, metal scrap, bars and sheet metal were placed in the emergency route.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Aug 27, 2025
- Abate by
- Sep 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: On or about April 3, 2025, on the south side of the work area: (a) The southwest exit sign was not illuminated, failing to provide clear visibility to direct employees out of the work area in an emergency, such as a fire or power outage. (b) The southeast exit sign was not illuminated, failing to provide clear visibility to direct employees out of the work area in an emergency, such as a fire or power outage. (c) The south exit sign was not illuminated, failing to provide clear visibility to direct employees out of the work area in an emergency, such as a fire or power outage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 A03 I
- Issued
- Aug 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: (a) On or about April 3, 2025, in the men's restroom on the southeast side of the work area was not kept in a dry condition. The toilet leaked onto the floor after being flushed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.184 E01
- Issued
- Aug 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: (a) On or about April 3, 2025, at the south side of the work area, employees used alloy steel chain slings to move scrap filled metal container and the sling did not have permanently affixed durable identification stating size, grade, rated capacity, and reach.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pinson Valley Fabricators, INC.
View Pinson Valley Fabricators, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348154030.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.