LONE STAR, TX —
OSHA Inspection: FRIEDMAN INDUSTRIES INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FRIEDMAN INDUSTRIES INCORPORATED in 2631 FM 250 MILL #2, LONE STAR, TX 75668 (NAICS 331210). OSHA activity number 348154105.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRIEDMAN INDUSTRIES INCORPORATED
- Site address
- 2631 FM 250 MILL #2
- City
- LONE STAR
- State
- TX
- ZIP
- 75668
- Mailing
- P. O. BOX 0388, LONE STAR, TX 75668
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 70
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Sep 2, 2025
- Penalty
- Initial $7,945 · Current $4,767 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about March 31, 2025, an employee was not protected from being caught in a pipe clamp while operating the south end facing/beveling machine in that its point of operation was not guarded to prevent employee(s) from having any part of their body in danger zone(s) as it cycled.
Recent events (2)
- — I (S) $4767
- — Z (S) $7945
1910.303 G02 I
- Issued
- Sep 2, 2025
- Penalty
- Initial $6,621 · Current $3,973 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) On or about April 2, 2025, employees were not protected from 480 Volts of electrical energy through accidental contact or arc in that the face plate for the top two main breakers of the breaker panel in the electrical room of Mill 2 was missing.