OSHA Inspection: AMRAN, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMRAN, LLC in 12320 CARDINAL MEADOW DRIVE, SUITE 100, SUGAR LAND, TX 77478 (NAICS 335311). OSHA activity number 348154444.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amran, LLC — free Get an email when a new federal OSHA severe-injury report for Amran, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AMRAN, LLC
Site address
12320 CARDINAL MEADOW DRIVE, SUITE 100
City
SUGAR LAND
State
TX
ZIP
77478
Mailing
12320 CARDINAL MEADOW DRIVE, SUITE 100, SUGAR LAND, TX 77478
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335311
Employees
70
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 4 instances 24 exposed
Issued
Jul 21, 2025
Abate by
Sep 5, 2025
Penalty
Initial $7,945 · Current $3,973 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to Items A-D of this section:  a) On or about April 2, 2025, in the winding department, the energy control procedure for winding and taping machines did not include a specific statement of the intended use of the procedure when employees performed machine maintenance activities.  b) On or about April 2, 2025, in the winding department, the energy control procedure for winding and taping machines did not include specific procedural steps for shutting down and isolating the machines when employees performed machine maintenance activities.  c) On or about April 2, 2025, in the winding department, the energy control procedure for winding and taping machines did not include procedural steps for placing lockout devices or tagout devices when employees fixed the crossover on the machines.  d) On or about April 2, 2025, in the winding department, the energy control procedure for winding and taping machines did not include procedural steps for verifying effectiveness of energy control measures when employees fixed the crossover on the machines.
Recent events (2)
  • — I (S) $3972.5
  • — Z (S) $7945

1910.147 C06 I

Serious Gravity 5 1 instance 24 exposed
Issued
Jul 21, 2025
Abate by
Sep 5, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed:  a) On or about April 2, 2025, in the winding department, the energy control procedure for winding and taping machines was not inspected at least annually to ensure that the requirements of this standard were being followed when employees performed machine maintenance activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 2 instances 22 exposed
Issued
Jul 21, 2025
Abate by
Sep 5, 2025
Penalty
Initial $7,945 · Current $1,387 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees:  a) On or about April 2, 2025, in the winding department, the machine operators did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control when they fixed the crossover on the winding machines.  b) On or about April 2, 2025, in the winding department, the machine operators were not instructed in the purpose and use of the energy control procedure when the winding machines were being serviced.
Recent events (2)
  • — I (S) $1386.5
  • — Z (S) $7945

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 21, 2025
Abate by
Aug 14, 2025
Penalty
Initial $7,945 · Current $3,973 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a) On or about March 25, 2025, in the winding department, the electrical energy source of JG7204 winding machine was not isolated when an employee was fixing a crossover on the machine.
Recent events (2)
  • — I (S) $3972.5
  • — Z (S) $7945

1910.212 A01

Serious Gravity 5 1 instance 22 exposed
Issued
Jul 21, 2025
Penalty
Initial $7,945 · Current $3,973 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about April 2, 2025, in the winding department, the rotating magazine of winding machine was not guarded when employees were operating the winding machines.
Recent events (2)
  • — I (S) $3972.5
  • — Z (S) $7945

1904.29 B01

Other-than-serious 1 instance 70 exposed
Issued
Jul 21, 2025
Abate by
Aug 14, 2025
Penalty
Initial $1,324 · Current $662 Reduced
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation:  a) On or about April 2, 2025, Column F of OSHA 300 Form for 2025 was not sufficiently detailed in describing events, materially impairing understandability of cause of the injuries.
Recent events (2)
  • — I (O) $662
  • — Z (O) $1324

1904.40 A

Other-than-serious 1 instance 70 exposed
Issued
Jul 21, 2025
Penalty
Initial $1,324 · Current $662 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records kept under part 1904 within four business hours:  a) On or about April 3, 2025, the employer did not provide OSHA 301 forms within four business hours upon the request.
Recent events (2)
  • — I (O) $662
  • — Z (O) $1324

1910.145 C02 I

Other-than-serious 1 instance 22 exposed
Issued
Jul 21, 2025
Penalty
Initial $744 · Current $372 Reduced
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:  a) On or about April 2, 2025, in the winding department, caution signs against unsafe practice of placing fingers or hands in the danger zone were not posted on the winding machines.
Recent events (2)
  • — I (O) $372
  • — Z (O) $744