HILL AIR FORCE BASE, UT —
OSHA Inspection: U.S. DEPT. OF THE AIR FORCE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of U.S. DEPT. OF THE AIR FORCE in BUILDING 240 CELL 103, HILL AIR FORCE BASE, UT 84056 (NAICS 921190). OSHA activity number 348156027.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPT. OF THE AIR FORCE
- Site address
- BUILDING 240 CELL 103
- City
- HILL AIR FORCE BASE
- State
- UT
- ZIP
- 84056
- Mailing
- OO-ALC SAFETY OFFICE BLDG 180 RM 222, HILL AIR FORCE BASE, UT 84056
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 921190
- Employees
- 100
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 20, 2025
- Abate by
- Oct 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section: (a) Building 240 - Test Cell 103: On or about March 25, 2025, the lockout procedure for the Air Turbine Starter test stand (SN 201022) did not clearly identify all of the specific steps to be followed by employees to isolate and disable the energy sources to safely de-energize the equipment and control hazardous pneumatic energy. The procedure also lacked specific steps to relieve hazardous residual pneumatic energy contained in the control air system prior to equipment opening and specific verification steps were not prescribed to determine the effectiveness of the energy control measures. This condition resulted in the release of stored pneumatic energy which caused an employee to be struck by a 4" braided stainless steel pipe, requiring hospitalization.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Aug 20, 2025
- Abate by
- Oct 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Building 240 - Test Cell 103: On or about March 25, 2025, the employer did not ensure that employees servicing an Air Turbine Starter test stand (SN 201022) were trained in the recognition of applicable hazardous energy sources and methods and means necessary for energy isolation and control. This condition exposed employees to struck-by hazards from 4" braided stainless steel piping when pneumatic pressure was released from the process air system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 II D
- Issued
- Aug 20, 2025
- Abate by
- Oct 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) Building 240 - Test Cell 103: On or about March 25, 2025 and at times prior, the employer did not ensure that employees servicing an Air Turbine Starter test stand (SN 201022) affixed personal lockout devices to electrical and pneumatic lockout points before working on the machine or equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at U.S. Dept. of the AIR Force
View U.S. Dept. of the AIR Force's full OSHA safety record →
More inspections in this industry (NAICS 921190)
More inspections in UT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348156027.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.