EAU CLAIRE, WI —
OSHA Inspection: GB BUILDERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GB BUILDERS in 1242 W CLAIREMONT AVE, EAU CLAIRE, WI 54701 (NAICS 238160). OSHA activity number 348158429.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GB BUILDERS
- Site address
- 1242 W CLAIREMONT AVE
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 4226 95TH STREET, CHIPPEWA FALLS, WI 54729
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B10
- Issued
- Aug 11, 2025
- Penalty
- Initial $1,929 · Current $1,350 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system; and/or on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Northwest slope of rooftop; On or about April 4, 2025, fall protection systems were not used during reroofing operations, while existing roofing materials were being manually removed from a 4/12 sloped roof that had a peak height of 11 feet, 1 inch and the eave height was 8 feet, 10 inches above the ground.
Recent events (2)
- — I (S) $1350.3
- — Z (S) $1929
1926.503 A01
- Issued
- Aug 11, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: (a)Throughout the establishment; On or about April 4, 2025, fall hazard awareness and/or fall prevention training was not provided to employees before they performed roofing activities at heights greater than 6 feet above the lower level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Aug 11, 2025
- Penalty
- Initial $1,447 · Current $1,013 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Northwest side of roof; On or about April 4, 2025, the siderails of a Keller brand, 10-foot fiberglass stepladder used to get on and off the roof did not extend at least 3 feet above the roofs eave, where they accessed the roof, which was 8 foot, 10 inches above ground level.
Recent events (2)
- — I (S) $1012.9
- — Z (S) $1447
1926.1053 B15
- Issued
- Aug 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: (a) Northwest side of roof; On or about April 4, 2025, a Keller brand, 10-foot fiberglass stepladder used to get on and off the roof and support a work plank was not inspected for visible defects. The ladder had a bent rear horizontal brace and two locations on the back siderails were cracked through where the rivets attached rear horizontal braces to the rails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Aug 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: (a) Northwest side of roof; On or about April 4, 2025, a damaged Keller brand, 10-foot fiberglass stepladder was not immediately marked as defective and/or removed from service. The ladder was used to get on and off the roof and support a work plank while it had a bent rear horizontal brace and two locations on the back siderails were cracked through where the rivets attached rear horizontal braces to the rails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at GB Builders
View GB Builders's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348158429.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.