WEST GREENWICH, RI —
OSHA Inspection: L.K. GOODWIN CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of L.K. GOODWIN CO., INC. in 20 TECHNOLOGY WAY, WEST GREENWICH, RI 02817 (NAICS 332323). OSHA activity number 348162892.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- L.K. GOODWIN CO., INC.
- Site address
- 20 TECHNOLOGY WAY
- City
- WEST GREENWICH
- State
- RI
- ZIP
- 02817
- Mailing
- 20 TECHNOLOGY WAY, WEST GREENWICH, RI 02817
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 18
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 19, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $9,847 · Current $4,924 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Piranha Ironworker 70: On or about April 7, 2025, employees were exposed to point of operation hazards associated with an unguarded ironworker machine. b) Clausing Drill Press: On or about April 7, 2025, employees were exposed to flying chip and rotating part hazards associated with an unguarded drill press.
Recent events (2)
- — I (S) $4923.5
- — Z (S) $9847
1910.254 D09 III
- Issued
- Jun 19, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $8,441 · Current $4,221 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced. a) Welder 1: On or about April 7, 2025, employees were exposed to electrical shock hazards when using welding leads with damaged insulation that were not replaced. b) Welder 2: On or about April 7, 2025, employees were exposed to electrical shock hazards when using welding leads with damaged insulation that were not replaced. c) Welder 3: On or about April 7, 2025, employees were exposed to electrical shock hazards when using welding grounds with damaged insulation that were not replaced.
Recent events (2)
- — I (S) $4220.5
- — Z (S) $8441
1910.38 F01
- Issued
- Jun 19, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $790 · Current $395 Reduced
General-duty citation text
29 CFR 1910.38(f)(1): The employer did not review the Emergency Action Plan initially with each new employee and at the beginning of their assignment. a) Jobsite: On or about April 7, 2025, the employer did not ensure all employees were trained in the company Emergency Preparedness and Action Plan.
Recent events (2)
- — I (O) $395
- — Z (O) $790
1910.147 C07 I
- Issued
- Jun 19, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. a) Jobsite: On or about April 7, 2025, the employer did not provide adequate lockout tagout training to all authorized and affected employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jun 19, 2025
- Penalty
- Initial $790 · Current $395 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. a) Flexo 40: On or about April 7, 2025, employees were exposed to electrical hazards when a power strip was plugged in with two extension cords plugged into the power strip b) Flexo 50 right side: On or about April 7, 2025, employees were exposed to electrical hazards when a power strip was plugged into an extension cord, with three additional extension cords plugged into the power strip. c) Flexo 50 middle: On or about April 7, 2025, employees were exposed to electrical hazards when a power strip was plugged into an extension cord, with an extension cord and fan plugged into the power strip d) Back Building: On or about April 7, 2025, employees were exposed to electrical hazards when a power strip was plugged into an extension cord.
Recent events (2)
- — I (O) $395
- — Z (O) $790
1910.305 B02 I
- Issued
- Jun 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy. a) Front Wall Drill Press: On or about April 7, 2025, the employer did not ensure junction boxes were completely enclosed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jun 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Flexo 50 right wall: On or about April 7, 2025, a power strip was used as fixed wiring to energize extension cords. b) Grinding Cart: On or about April 7, 2025, a power strip was used as fixed wiring to energize extension cords. c) Flexo 50 middle: On or about April 7, 2025, a power strip was used as fixed wiring to energize extension cords. d) Flexo 40: On or about April 7, 2025, a power strip was used as fixed wiring to energize extension cords. e) Back Building: On or about April 7, 2025, a power strip was used as fixed wiring to energize extension cords. f) Wall behind Flexo 50: On or about April 7, 2025, an extension cord was plugged in and wrapped around a steel beam and electrical tubing to energize a mounted fan.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at L.K. Goodwin CO., INC.
View L.K. Goodwin CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348162892.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.