Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRI-MACK PLASTICS MANUFACTURING CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRI-MACK PLASTICS MANUFACTURING CORP. in 55 BROADCOMMON RD UNIT 1, BRISTOL, RI 02809 (NAICS 326199). OSHA activity number 348163767.

Watch Tri-Mack Plastics Manufacturing Corp. — free Get an email when a new federal OSHA severe-injury report for Tri-Mack Plastics Manufacturing Corp. is published. One employer, no account, unsubscribe in one click.
Site address
55 BROADCOMMON RD UNIT 1
City
BRISTOL
State
RI
ZIP
02809
Mailing
55 BROADCOMMON RD UNIT 1, BRISTOL, RI 02809
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
113
Ownership type
A

3 citations on file for this inspection.

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Jul 10, 2025
Penalty
Initial $1,118 · Current $783 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years.  a) Warehouse:  On or about April 8, 2025, the employer had not evaluated the performance of forklift operators within the past three years.
Recent events (2)
  • — I (O) $782.6
  • — Z (O) $1118

1910.305 G01 IV A

Other-than-serious 3 instances 3 exposed
Issued
Jul 10, 2025
Penalty
Initial $1,118 · Current $783 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  a) Engel Machine Workstation: On or about April 8, 2025, employees were exposed to electrical hazards while an extension cord without GFCI protection was being used  to provide power to a Dewenwils Cord Reel and a  Dri-Air Industries Machine, Model HPD-4.  b) Quality Control Cubicles: On or about April 8, 2025, employees were exposed to electrical hazards while an extension cord without GFCI protection was being used to provide power to multiple cubicles in the Quality Control Area.  c) Guhring Tool Vending Machine: On or about April 8, 2025, employees were exposed to electrical hazards while an extension cord without GFCI protection was being used to provide power to a Guhring Tool Vending Machine.
Recent events (2)
  • — I (O) $782.6
  • — Z (O) $1118

1910.305 G01 IV D

Other-than-serious 2 instances 2 exposed
Issued
Jul 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces.    a) Engel Machine Workstation: On or about April 8, 2025, employees were exposed to electrical hazards while an extension cord was attached to an electrical conduit with plastic tie wraps.  b) Quality Control Cubicles: On or about April 8, 2025, employees were exposed to electrical hazards while an extension cord was attached to a wall while providing power to the Quality Control Machines.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tri-Mack Plastics Manufacturing Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348163767.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.