Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KAFKA CONVEYORS & EQUIPMENT INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KAFKA CONVEYORS & EQUIPMENT INC in 214501 ST HWY 107, MOSINEE, WI 54455 (NAICS 333922). OSHA activity number 348164617.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kafka Conveyors & Equipment INC — free Get an email when a new federal OSHA severe-injury report for Kafka Conveyors & Equipment INC is published. One employer, no account, unsubscribe in one click.
Site address
214501 ST HWY 107
City
MOSINEE
State
WI
ZIP
54455
Mailing
213202 ST HWY 107, MOSINEE, WI 54455
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333922
Employees
63
Ownership type
A

8 citations on file for this inspection.

1910.106 E02 II B 2

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Dec 31, 2025
Penalty
Initial $5,628 · Current $3,376 Reduced
29 CFR  1910.106(e)(2)(ii)(b)(2): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed: 120 gallons of Category 2, 3, or 4 flammable liquids in containers.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employee working in the old Paint Building were exposed to potential burns hazards when a 55 gallon drum of Barsol A-4607, a 55 gallon drum of Diamond Vogel Mult-E-Prime 500 Hi-Build Epoxy Gray and two 55 gallon drums of Barsol LTJV514 Lacquer Thinner were found being stored improperly.  The flammable liquids exceeded the amount allowed outside of a cabinet or storage room.
Recent events (2)
  • — I (S) $3376
  • — Z (S) $5628

1910.106 E06 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Aug 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees were exposed to potential burns hazards while dispensing from a 55 Gallon drum of Barsol A-4607 without having first grounding the barrel and bonding to barrel to the dispensing container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2025
Abate by
Aug 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.106(e)(9)(iii):"Waste and residue." Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees were exposed to burn hazards when a combustible waste residue can, used to store waste material coated in flammable liquids, had not been emptied on a daily basis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(4)(i): Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees in the Old Building's Fabrication area were exposed to potential burn hazards when the employer did not ensure that oxygen cylinders and Propylene were stored separately.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 18, 2025
Abate by
Aug 15, 2025
Penalty
Initial $5,628 · Current $3,376 Reduced
29 CFR  1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard: 1910.179(j)(2)(i)-1910.179(j)(2)(iv).  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees in the Old Building's Fabrication area were exposed to potential struck by hazards when overhead cranes were not inspected on a frequent basis to ensure they were operating safely and without defects.
Recent events (2)
  • — I (S) $3376
  • — Z (S) $5628

1910.179 M01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 18, 2025
Abate by
Aug 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.179(m)(1): Running ropes. A thorough inspection of all ropes shall be made at least once a month and a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected shall be kept on file where readily available to appointed personnel. Any deterioration, resulting in appreciable loss of original strength, shall be carefully observed and determination made as to whether further use of the rope would constitute a safety hazard. Some of the conditions that could result in an appreciable loss of strength are the following: 1910.179(m)(1)-1910.179(m)(1)(vi).  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees in the Old Building's Fabrication area were exposed to potential struck-by hazards when the wire ropes of overhead cranes were not inspected on a monthly basis to ensure that they had not experienced appreciable loss of strength from items such as, but not limited to, kinks and broken strands.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 6 exposed
Issued
Jul 18, 2025
Penalty
Initial $3,376 · Current $2,026 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees in the Old Building's Fabrication area were exposed to potential shock and fire hazards when a wall mounted garage tube heater was plugged into an extension cord instead of a fixed outlet.
Recent events (2)
  • — I (S) $2026
  • — Z (S) $3376

1910.305 G01 IV C

Serious Gravity 1 1 instance 6 exposed
Issued
Jul 18, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(C): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where run through doorways, windows, or similar openings.  On or about April 8, 2025, at an establishment located at 214501 St Hwy 107, Mosinee, WI, employees in the Old Building's Fabrication area were exposed to potential shock and fire hazards when a wall mounted garage tube heater was plugged into an extension cord
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Kafka Conveyors & Equipment INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348164617.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.