IOWA COLONY, TX —
OSHA Inspection: UNITED CONSTRUCTORS OF TEXAS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of UNITED CONSTRUCTORS OF TEXAS, INC. in 2002 MERIDIANA PKWY, IOWA COLONY, TX 77583 (NAICS 236220). OSHA activity number 348166430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED CONSTRUCTORS OF TEXAS, INC.
- Site address
- 2002 MERIDIANA PKWY
- City
- IOWA COLONY
- State
- TX
- ZIP
- 77583
- Mailing
- 6989 W LITTLE YORK RD, STE F, HOUSTON, TX 77040
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Oct 7, 2025
- Abate by
- Nov 3, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about April 8, 2025, on the east side of the jobsite, employees worked in an excavation that was more than 4 feet deep without a safe means of egress when connecting a fire hydrant to a water line.
Recent events (2)
- — C (S) $11585
- — Z (S) $11585
1926.651 H01
- Issued
- Oct 7, 2025
- Abate by
- Nov 3, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: a) On or about April 8, 2025, on the east side of the job site, employees were connecting a fire hydrant to a water line at the base of an excavation without water being removed.
Recent events (2)
- — C (S) $11585
- — Z (S) $11585
1926.652 A01
- Issued
- Oct 7, 2025
- Abate by
- Nov 3, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) On or about April 8, 2025, on the east side of the jobsite, employees were connecting a fire hydrant to a water line in an excavation over 5 feet deep without a protective system in place.
Recent events (2)
- — C (S) $11585
- — Z (S) $11585
More inspections in this industry (NAICS 236220)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348166430.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.