OSHA Inspection: UNITED CONSTRUCTORS OF TEXAS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of UNITED CONSTRUCTORS OF TEXAS, INC. in 2002 MERIDIANA PKWY, IOWA COLONY, TX 77583 (NAICS 236220). OSHA activity number 348166430.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Constructors of Texas, INC. — free Get an email when a new federal OSHA severe-injury report for United Constructors of Texas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2002 MERIDIANA PKWY
City
IOWA COLONY
State
TX
ZIP
77583
Mailing
6989 W LITTLE YORK RD, STE F, HOUSTON, TX 77040
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 7, 2025
Abate by
Nov 3, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) On or about April 8, 2025, on the east side of the jobsite, employees worked in an excavation that was more than 4 feet deep without a safe means of egress when connecting a fire hydrant to a water line.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.651 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 7, 2025
Abate by
Nov 3, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation:  a) On or about April 8, 2025, on the east side of the job site, employees were connecting a fire hydrant to a water line at the base of an excavation without water being removed.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 7, 2025
Abate by
Nov 3, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a) On or about April 8, 2025, on the east side of the jobsite, employees were connecting a fire hydrant to a water line in an excavation over 5 feet deep without a protective system in place.