Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QIHUA CHEN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QIHUA CHEN in 1561 E 32ND ST, BROOKLYN, NY 11234 (NAICS 236118). OSHA activity number 348167164.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qihua Chen — free Get an email when a new federal OSHA severe-injury report for Qihua Chen is published. One employer, no account, unsubscribe in one click.
Establishment
QIHUA CHEN
Site address
1561 E 32ND ST
City
BROOKLYN
State
NY
ZIP
11234
Mailing
73 BAY 20TH ST, APT 1F, BROOKLYN, NY 11214
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2025
Penalty
Initial $2,412 · Current $2,412
29 CFR  1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.  Location: Worksite; basement.   a) On or about 04/09/2025, two live circuit breaker panels were not guarded against accidental contact by a suitable enclosure.
Recent events (1)
  • — Z (S) $2412

1926.405 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 29, 2025
Penalty
Initial $2,412 · Current $2,412
29 CFR  1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy.  Location: Worksite; basement.  a) On or about 04/09/2025, energized outlet boxes were not equipped by a cover, faceplate or fixture canopy to protect against electrical shock hazards.
Recent events (1)
  • — Z (S) $2412

1926.1052 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 29, 2025
Penalty
Initial $2,412 · Current $2,412
29 CFR  1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge.  Location: Worksite; basement and first floor.  a) On or about 04/09/2025, the stair case leading from the basement to the first floor was not equipped with a stair rail, exposing employees to falls of up to 6ft.
Recent events (1)
  • — Z (S) $2412

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348167164.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.