Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE METAL FABRICATING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACCURATE METAL FABRICATING, INC. in 4620 19TH STREET, CICERO, IL 60804 (NAICS 332710). OSHA activity number 348167719.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate Metal Fabricating, INC. — free Get an email when a new federal OSHA severe-injury report for Accurate Metal Fabricating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4620 19TH STREET
City
CICERO
State
IL
ZIP
60804
Mailing
4620 19TH STREET, CICERO, IL 60804
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
140
Ownership type
A

2 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 25, 2025
Penalty
Initial $6,384 · Current $3,200 Reduced
29 CFR  1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  a. Paint Booth Area -  On or about April 9, 2025, an employee applying powder coating to  product in the spray booth was provided a full-face tight-fitting respirator with organic vapor/P95 cartridge for voluntary use. The employer did not establish and implement a written respirator program that includes at a minimum, the following elements:  (i) Medical evaluations to ensure employees are medically able to use a respirator.  (ii) Procedures for cleaning, storing, and maintaining the respirator to prevent a health hazard to the user.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $6384

1910.134 K06

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 25, 2025
Abate by
Jul 22, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a. Paint Booth Area - On or about April 9, 2025, an employee powder coating product was provided full-face tight-fitting respirators with organic vapor/P95 cartridge for voluntary use. The employer did not provide the information contained in 29 CFR 1910.134, Appendix D ("Information for Employees Using Respirators When Not Required Under the Standard").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348167719.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.