SAN ANTONIO, TX —
OSHA Inspection: R&K INDUSTRIES LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of R&K INDUSTRIES LLC in 12103 RADIUM, SAN ANTONIO, TX 78216 (NAICS 562910). OSHA activity number 348171703.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R&K INDUSTRIES LLC
- Site address
- 12103 RADIUM
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78216
- Mailing
- 12103 RADIUM, SAN ANTONIO, TX 78216
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 E01
- Issued
- Aug 13, 2025
- Abate by
- Sep 9, 2025
- Penalty
- Initial $5,675 · Current $2,838 Reduced
1980
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about April 8, 2025, the employees utilized tight fitting half-mask respirators without a medical evaluation being provided prior to use.
Recent events (2)
- — I (O) $2837.5
- — Z (S) $5675
1910.134 F01
- Issued
- Aug 13, 2025
- Abate by
- Sep 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about April 8, 2025, employees were not administered fit testing procedures prior to wearing half mask respirators while performing restoration and cleaning services.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Aug 13, 2025
- Abate by
- Sep 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A):Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: On or about April 8, 2025, and at times prior thereto, employees with facial hair wore half-mask tight fitting respirators while performing restoration services.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at R&K Industries LLC
View R&K Industries LLC's full OSHA safety record →
More inspections in this industry (NAICS 562910)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348171703.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.