CINCINNATI, OH —
OSHA Inspection: KEP ELECTRIC, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KEP ELECTRIC, INC. in 7539 DONEGAL DRIVE, CINCINNATI, OH 45233 (NAICS 238210). OSHA activity number 348175654.
Where did this inspection happen?
- Establishment
- KEP ELECTRIC, INC.
- Site address
- 7539 DONEGAL DRIVE
- City
- CINCINNATI
- State
- OH
- ZIP
- 45233
- Mailing
- 1114 FERRIS RD., AMELIA, OH 45102
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $11585.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b) Accident Prevention Responsibilities. (2):Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. a) On or about April 8, 2025, the employer failed to ensure that a competent person conducted frequent and regular inspections of the jobsite, materials, and equipment to detect and correct hazardous ladder conditions-specifically, an extension ladder set on uneven ground and positioned at an improper 4 : 1 angle. As a result, an employee fell approximately 20 feet while installing an exterior electrical receptacle and required hospitalization.
Recent events (2)
- — I (S) $0
- — Z (S) $11585
1926.1053 B05 I
- Issued
- Abate by
- Penalty
- Initial $11585.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b) Use. (5)(i):Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). On or about April 8 2025, the employer failed to ensure that a non-self-supporting extension ladder was positioned at the required 4 : 1 (one-quarter working-length) angle and on stable, level footing while an employee used it to install an exterior electrical receptacle on a newly constructed residence. As a result, the employee fell approximately 20 feet and required hospitalization.
Recent events (2)
- — I (S) $0
- — Z (S) $11585
1926.1053 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)Use. (6):Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement. a) On or about April 8 2025, the employer failed to ensure that a non-self-supporting extension ladder used to install an exterior electrical receptacle was placed on a stable, level surface or otherwise secured to prevent displacement. As a result, the ladder shifted and an employee fell approximately 20 feet and required hospitalization.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at KEP ELECTRIC, INC.
NEWPORT, KY—2013-08-23 00:00:00
KEP ELECTRIC INC
View KEP ELECTRIC, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348175654.