Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: POLYMERICS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POLYMERICS INC. in 2828 SECOND STREET, CUYAHOGA FALLS, OH 44221 (NAICS 326299). OSHA activity number 348188434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Polymerics INC. — free Get an email when a new federal OSHA severe-injury report for Polymerics INC. is published. One employer, no account, unsubscribe in one click.
Establishment
POLYMERICS INC.
Site address
2828 SECOND STREET
City
CUYAHOGA FALLS
State
OH
ZIP
44221
Mailing
2828 SECOND STREET, CUYAHOGA FALLS, OH 44221
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
326299
Employees
78
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2025
Abate by
Sep 18, 2025
Penalty
Initial $6,620 · Current $4,634 Reduced
29 CFR  1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   On or about April 14, 2025, the employer did not ensure hazardous energy control (LOTO) procedures were utilized when an employee was attempting to perform a servicing operation to unjam the chute door area on the Banbury Mixer #9, F Series, Serial number 13557.
Recent events (2)
  • — I (S) $4634
  • — Z (S) $6620

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 1, 2025
Abate by
Sep 18, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29CFR 1910.147(c)(4)(ii)(A), 29CFR 1910.147(c)(4)(ii)(B), and 29CFR 1910.147(c)(4)(ii)(C).  On or about April 14, 2025, the employer did not ensure that the hazardous energy control procedure for the #9 Banbury Mixer F Series, Serial number 13557 in the western corner of the building on the 2nd floor, included a specific statement of the intended use of the procedure [per 1910.147(c)(4)(ii)(A)] or specific procedural steps for shutting down the equipment [per 29CFR 1910.147(c)(4)(ii)(B)] or the specific procedural steps for the removal of lockout devices [per 1910.147(c)(4)(ii)(C)].
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 1, 2025
Abate by
Sep 18, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about April 14, 2025, the employer did not ensure the periodic inspection of the energy control procedure for the Banbury Mixer #9, F Series, Serial number 13557, in the Western corner of the building on the 2nd floor, was conducted to correct any inadequacies in the procedure. The employer's energy control procedure was inadequate in that the employer did not ensure that the hazardous energy control procedure included a specific statement of the intended use of the procedure [per 1910.147(c)(4)(ii)(A)] or specific procedural steps for shutting down the equipment [per 29CFR 1910.147(c)(4)(ii)(B)] or the specific procedural steps for the removal of lockout devices [per 1910.147(c)(4)(ii)(C)].
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
Aug 1, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:   On or about April 14, 2025, the employer did not provide Appendix D of  29 CFR 1910.134 to employees before working on the Banbury Mixer #9, F Series, Serial number 13557 and voluntarily wear a N-95 respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Polymerics INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348188434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.