LAKELAND, FL —
OSHA Inspection: PROGEN INDUSTRIES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PROGEN INDUSTRIES LLC in 2855 BROOKS STREET, LAKELAND, FL 33803 (NAICS 335312). OSHA activity number 348188723.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROGEN INDUSTRIES LLC
- Site address
- 2855 BROOKS STREET
- City
- LAKELAND
- State
- FL
- ZIP
- 33803
- Mailing
- 600 PRAIRIE INDUSTRIAL PARKWAY, MULBERRY, FL 33860
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.28 B01 I
- Issued
- Sep 30, 2025
- Penalty
- Initial $6,621 · Current $4,635 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) At the site on 2855 Brooks St, Lakeland, Florida in the fabrication area on or about 4/17/25, the employer exposed employees to fall hazards, in that, employees were not protected from falling from the walking working surface on top of the Generator roof approx. 10'9" feet in height while conducting drilling and tapping to topside.
Recent events (2)
- — I (S) $4634.7
- — Z (S) $6621
1910.178 L01 I
- Issued
- Sep 30, 2025
- Penalty
- Initial $6,621 · Current $4,635 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) At the site on 2855 Brooks St, Lakeland, Florida in the fabrication area on or about 4/17/25, the employer exposed employees to struck-by/crush-by hazards, in that, employees who operated powered industrial trucks on site had not been trained on the type of powered industrial trucks that they operated.
Recent events (2)
- — I (S) $4634.7
- — Z (S) $6621
1910.333 A
- Issued
- Sep 30, 2025
- Penalty
- Initial $5,296 · Current $3,707 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a) At the site on 2855 Brooks St, Lakeland, Florida in the fabrication area on or about 4/17/25, employer exposed employees to an electrical shock hazard, in that, the ProGen Tagout procedure for electrical was not complied with, in that an electrical cable was coiled and a red tape with the words "Do not use" wrapped around it placed on an electrical switch box.
Recent events (2)
- — I (S) $3707.2
- — Z (S) $5296
1910.334 A02 II
- Issued
- Sep 30, 2025
- Penalty
- Initial $5,296 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) At the site on 2855 Brooks St, Lakeland, Florida in the fabrication area on or about 4/17/25, employer exposed employees to an electrical shock hazard in that a damaged extension cable was plugged into an energized outlet and had not been removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $5296
1910.305 B02 I
- Issued
- Sep 30, 2025
- Penalty
- Initial $5,296 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) At the site on 2855 Brooks St, Lakeland, Florida in the fabrication area on or about 4/17/25, employer exposed employees to an electrical shock and fire hazards, in that, the outlet box located on the Tank Alert XTM post had a cover that was coming off..
Recent events (2)
- — I (S) $0
- — Z (S) $5296
More inspections at Progen Industries LLC
View Progen Industries LLC's full OSHA safety record →
More inspections in this industry (NAICS 335312)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348188723.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.